A Field Study on Thermal Comfort of Traditional Metal Processing Factories

Abstract:

Article Preview

A traditional metal processing factory is a hot workplace. Previously, the rationality of the work-rest time regimen and the hazard of workload on employee health have been evaluated; however, thermal comfort of workers in such a hot workplace has not been discussed. This paper uses the standard new effective temperature as the thermal environment index to investigate the neutral temperature, preferred temperature, and comfortable temperature range. The doors and windows in traditional metal processing factories are always open; therefore, the neutral temperature is almost the same as the neutral temperature in semi-outdoor and outdoor environments. In addition, the preferred temperature is slightly higher than the neutral temperature. We also discovered that the comfortable temperature range in traditional metal processing factories is larger than that in office environments, but smaller than that in semi-outdoor and outdoor environments.

Info:

Periodical:

Edited by:

Guangfan Li, Chaohe Chen, Bifeng Jiang and Qizhong Shen

Pages:

443-448

Citation:

C. C. Su et al., "A Field Study on Thermal Comfort of Traditional Metal Processing Factories", Applied Mechanics and Materials, Vols. 587-589, pp. 443-448, 2014

Online since:

July 2014

Export:

Price:

$41.00

* - Corresponding Author

[1] The Climate Statistics of Central Weather Bureau, Information on http: /www. cwb. gov. tw (In Chinese).

[2] T.H. Karyono: Build. Environ. Vol. 35 (2000), pp.77-90.

[3] X.L. Ji, W.Z. Lou, Z.Z. Dai, B.G. Wang and S.Y. Liu: Build. Res. Inf. Vol. 34 (2006), pp.507-514.

[4] F.H. Mallick: Energy Build. Vol. 23 (1996), pp.161-167.

[5] X.J. Ye, Z.P. Zhou, Z.W. Lian, H.M. Liu, C.Z. Li and Y.M. Liu: Indoor Air Vol. 16 (2006), pp.320-326.

[6] A.G. Kwok and C. Chun: Sol. Energy Vol. 74 (2003), pp.245-252.

[7] E.L. and P.H.T. Zannin: Build. Environ. Vol. 39 (2004), pp.1055-1063.

[8] I.F. Mao, M.L. Chen, C.J. Chen, W.Y. Yeh, K.Y. Yang, Y.C. Chen, C.C. He, J.W. Huang, S.C. Wu and S.F. Jeng: J. Occup. Saf. Health Vol. 4 (1996), pp.1-12 (In Chinese).

[9] M.L. Chen, J.W. Huang, C.J. Chen, S.F. Cheng and I.F. Mao: J. Occup. Saf. Health Vol. 6 (1998), pp.115-129 (In Chinese).

[10] F.J. Wu, P.J. Tsai, H.H. Tu, M.J. Tong, W.Y. Yeh, S.H. Lin, W.Y. Chen, J.M. Sun and Y.J. Juang: J. Occup. Saf. Health Vol. 9 (2001), 119-138 (In Chinese).

[11] The Standard of Work-rest Time Regimen of Workers in Thermal Environments, Information on http: /laws. cla. gov. tw/Chi/FLAW/FLAWDAT0202. asp (In Chinese).

[12] A. Srivastava, R. Kumar, E. Joseph and A. Kumar: Ann. Occup. Hyg. Vol. 44 (2000), pp.449-453.

[13] R. Ayyappan, S. Sankar, P. Rajkumar and K. Balakrishnan: Global Health Action Vol. 2 (2009), doi: 10. 3402/gha. v2i0. (2060).

[14] American Conference of Governmental Industrial Hygienists (1999) Threshold limit values for chemical substances and physical agents and biological exposure indices, Cincinnati.

[15] J. Spagnolo and R. de Dear: Build. Environ. Vol. 38 (2003), pp.721-738.

[16] J. Nakano and S. Tanabe: ASHRAE Trans. Vol. 110 (2004), pp.543-553.

[17] E.M. Lin, S. Thorsson, F. Lindberg, T. Honjo, I. Eliasson and K. Umeki: Environ. Inf. Sci. Vol. 19 (2005), pp.53-58.

[18] J.F. Lee: Master thesis, Feng Chia University, Taichung, Taiwan (2008) (In Chinese).

[19] M.J. Cheng, J.H. Lo and J.F. Li: J. Archit. Vol. 69 (2009), pp.1-16 (In Chinese).

[20] S.C. Yen: Master thesis, Feng Chia University, Taichung, Taiwan (2009) (In Chinese).

[21] ISO 9920 (1995), International Organization for Standardization, Geneva.

[22] ISO 8996 (1990), International Organization for Standardization, Geneva.

[23] ISO 7726 (1998), International Organization for Standardization, Geneva.

[24] ISO 7730 (2005), International Organization for Standardization, Geneva.

[25] L.G. Berglund: ASHRAE Journal, August (1998), pp.35-41.

[26] K. Tsuzuki and T. Iwata: 9th International Conference on Indoor Air Quality and Climate, Monterey, California, June 30-July 5, Vol. 4 (2002), pp.647-52.

[27] E.R. Ballantyne, R.K. Hill and J.W. Spencer: Int. J. Biometeorol. Vol. 21 (1977), pp.29-43.

[28] ASHRAE Standard 55 (2004), American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta.