Study on the Effect of Different Water Treatment Technology on Removing 2-MIB

Article Preview

Abstract:

To compare the removal efficiency of 2-MIB by traditional water treatment, prechlorination, O3-BAC, MIEX pre adsorption and UV/H2O2 advanced oxidation process, the pilot-test of drinking water odor control technology were studied in this paper. The results showed that the traditional water treatment process had poor effect on removing 2-MIB, with about 10% removal rate, while the O3-BAC process was the best at removing 2-MIB, whose removal rate reached over 90%. And the 2-MIB removal rate of UV/H2O2 process was about 55% and that of prechlorination process was about 20%. However, the MIEX pretreatment process had almost no effect on removing 2-MIB.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

594-597

Citation:

Online since:

July 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] XIA Ping, YE Hui, ZHOU Xinyu, et al. Pilot-scale Study of UV/H2O2 on Removing Micro organic Pollutant in Water, Journal of China Water & Waste Water, Vol. 38(2012),119-122.

Google Scholar

[2] Rodriguez E, Onstad G, Kull T, et al. Oxidative elimination of cyanotoxins: Comparison of ozone, chlorine, Journal of chlorine dioxide and permanganate, Water Res, Vol. 41(2007), 3381-3393.

DOI: 10.1016/j.watres.2007.03.033

Google Scholar

[3] Yue S-Y. Exploration on the algae removal effect with composite water treatment process, Journal of Water Purificaition Technology, Vol. 25 (2006), 1-5.

Google Scholar