A Control Method to Suppress Resonance and Improve Current Quality for Inverter System with LCL Filter

Article Preview

Abstract:

The LCL filter is easy to resonate, especially in the new energy power system with multiple inverters. The LCL filter resonant formulas are derived in this paper and a novel double closed loop control strategy combing with the structure of the LCL filter was proposed at the base on feedback of capacitor current as a result. In the control system, the inner loop feedback the first differential voltage of filter inductor at the grid side to damp the resonance and nature of first differential voltage of filter inductor is explained; the grid current outer loop achieves direct control of the grid current for high power factor and utilization efficiency. The simulation results show that the grid-side inductor voltage differential feedback control have a better current control effect both in the condition of the normal power grid voltage and distorted grid voltage, and the fluctuations of power and dc voltage are reduced.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

3528-3533

Citation:

Online since:

September 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Serpa L A, Ponnaluri S.A modified direct power control strategy allowing the connection of three-phase inverters to the grid through LCL filters[J].IEEE Transactions on Industry Applications , 2007, 43(5):1388-1400.

DOI: 10.1109/tia.2007.904438

Google Scholar

[2] Dannehl J, Fuchs F W, Hansen S, et al.Investigation of active damping approaches for PI-based current control of grid-connected pulse width modulation converters With LCL filters[J].IEEE Trans. on Industry Applications, 2010, 46(4):1509-1517.

DOI: 10.1109/tia.2010.2049974

Google Scholar

[3] Chen Dong, Zhang Junming, Qian Zhaoming. Single Current Feedback Control Strategy for Grid-connected Inverters With LCL filters[J].Proceedings of the CSEE, 2013, 33(9) :10-16(in Chinese).

Google Scholar

[4] Wu Yunya, Xie Shaojun, Kan Jiarong, Guo Liang. A Full Grid Voltage Feed-forward Control Strategy With Inverter-side Current Feedback for LCL Grid-connected Inverters[J]. Proceedings of the CSEE, 2013, 33(6):54-60(in Chinese).

DOI: 10.1109/ecce-asia.2013.6579254

Google Scholar

[5] Wang Xuehua, Ruan Xinbo, Liu Shangwei. Control Strategy for Grid-connected Inverter to Suppress Current Distortion Effected by Background Harmonics in Grid Voltage[J]. Proceedings of the CSEE, 2011, 31(6):7-14(in Chinese).

DOI: 10.1109/tpel.2010.2077312

Google Scholar

[6] Xu Jinming, Xie Shaojun, Xiao Huafeng.Research on control mechanism of active damping for LCL filters[J].Proceedings of the CSEE, 2012, 32(9):27-33(in Chinese).

Google Scholar

[7] Karshenas H R, Saghafi H.Performance investigation of LCL filters in grid connected converters[C]/ IEEE Transmission & Distribution Conference and Exposition, Dallas, USA, (2006).

DOI: 10.1109/tdcla.2006.311646

Google Scholar

[8] Liu Fei, Duan Shanxu, Zha Xiaoming.Design of two-loop controller in grid-connected inverter with LCL filter[J].Proceedings of the CSEE, 2009, 29(S1):234-240(in Chinese).

DOI: 10.1109/ipemc.2009.5157762

Google Scholar