The Transient Characteristics Analysis of Doubly-Fed Induction Generator during the Asymmetric Voltage Sag

Article Preview

Abstract:

In order to analyze the control strategy of the low voltage ride through (LVRT) of DFIG during the asymmetric voltage sag, it is necessary to analyze the transient performance of a DFIG during the asymmetric voltage sag. In this paper, analyzed the influence of the asymmetric grid voltage to DFIG and the analysis method of the asymmetric voltage sag, and on the basis of positive and negative sequence mathematical model, analyzed the composition of stator output active and reactive power under the condition of asymmetric grid voltage. And built a DFIG asymmetric voltage drop simulation model of 1.5MW in MATLAB/Simulink, the simulation results shows that the stator voltage, current, active power and reactive power all present a double frequency ripple during the asymmetric voltage sag, consistent with theoretical analysis. It can provide theoretical basis for double-fed motor control strategy of asymmetric LVRT.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

3509-3514

Citation:

Online since:

September 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Morren. J, Sjoerd W.H. Ride through of wind turbines with doubly-fed induction generator during a voltage dip.IEEE Transacitons on Energy Conversion, vol. 20, no. 2, pp.435-441. (2005).

DOI: 10.1109/tec.2005.845526

Google Scholar

[2] Xie Bing, Fox B, Flynn D.Study of fault ride-through for DFIG wind turbines.IEEE Intenraitonla Conference on Electric Uitlity Deregulaiton Restructuring and Power Technolclgies, Hong Kong, China. (2004).

DOI: 10.1109/drpt.2004.1338531

Google Scholar

[3] Abbey C, Joos G. Efectoflow voltage ride through (LVRT) characteristic on voltage stability. IEEE Transacitons on Industry Applications, vol. 41, no. 3, pp.1-7. (2005).

DOI: 10.1109/pes.2005.1489659

Google Scholar

[4] Zhang Xin, Zhang Longyun, Yang Shuying, etc. Low voltage ride through technology overview of wind power. Electric Power System And Automation, vol. 20, no. 2, pp.128-130. (2008). (In Chinese).

Google Scholar

[5] Ma Chunming, Jie Da, Zhang Yanchi. Low voltage ride through technical overview of DFIG system. Electric Transmission, vol. 42, no. 5, pp.3-7. (2012). (In Chinese).

Google Scholar

[6] He Yikang, Hu Jiabing. Several hot problems in parallel operation of DFIG. China Journal of Electrical Engineering, vol. 32, no. 27, pp.1-15. (2012). (In Chinese).

Google Scholar

[7] Li Guangqi. Transient analysis of power system. Beijing: China Electricity Power Press, pp.33-43, 86-91, 119-120. (2006) . (In Chinese).

Google Scholar

[8] Wang Hongsheng, Zhang Wei, Hu Jiabing, He Yikang. Control strategy of DFIG wind turbine under unbalanced grid voltage fault. Power System Automation, vol. 34, no. 4, pp.97-102. (2010). (In Chinese).

DOI: 10.1109/iemdc.2009.5075201

Google Scholar

[9] Zhang Jianhua, Chen Xingyin, Liu Haoming, etc. Three-phase short circuit analysis of DFIG-based wind gerenation and the crowbar biggest resistance setting. Power System Automation, vol. 29, no. 4, pp.6-10. (2009). (In Chinese).

DOI: 10.1109/supergen.2009.5348167

Google Scholar

[10] Chen Sizhe. Wu Jie. Liu Jie. Low voltage through control of double-fed induction wind power system. Journal Of Solar Energy, vol. 30, no. 11, pp.1528-1534. (2009). (In Chinese).

Google Scholar

[11] Chen Boshi. Automatic control system of electric traction. Beijing: Machinery Industry Press, pp.200-204. (2003). (In Chinese).

Google Scholar