Applied-Information Technology in Concentration Depth Profile of Multi-Charged Mo Ion Implantation
Abstract:
Monte Carlo computer simulations based on the binary collision approximation, TRIDYN program, have been applied to calculate the concentration depth profiles of implanted multi-charged molybdenum ions in H13 steel. The sputtering effect of a high dose ion implantation and influence of multi-charged ions on the concentration depth profile of implanted molybdenum ions can both be considered in the TRIDYN simulation. For the Monte Carlo computer simulation, the chosen pseudo-projectiles are 500000. The chosen extraction voltages are 48kV and 25kV, respectively, and an implantation doses of 5×1017cm-2 to compare the results which have been published related to molybdenum ion implantation. TRIDYN program is better than SRIM program in the calculation of the concentration depth profiles of implanted multi-charged ions. And the calculation result of the TRIDYN program is different from the experiment result. The other factors of affecting the concentration depth profile have also been discussed finally.
Info:
Periodical:
Pages:
115-118
Citation:
Online since:
October 2014
Authors:
Price:
Сopyright:
© 2014 Trans Tech Publications Ltd. All Rights Reserved
Share: