Study on Dispersed Wind Power Connected to Power Grid

Article Preview

Abstract:

The necessity for grid codes of the dispersed wind power connected to power grid is described briefly and the definition of the dispersed wind power is discussed compared with the distributed wind power in China. Aimed at the dispersed wind power, the main technology indicators of wind power grid codes between Denmark (below 100kV), Germany (below 60kV) and China in aspects of access principle, connection mode, active power / frequency control, reactive power / voltage control, fault ride through and power quality are compared to provide reference for the modification and completion of the dispersed wind power grid code in China.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

262-268

Citation:

Online since:

October 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] DEFU. Connection of Wind Turbines to Low and Medium Voltage Networks, (1998).

Google Scholar

[2] EnergiNet. Grid connection of wind turbines to networks with voltages below 100 kV, Regulation TF 3. 2. 6, May 2004, p.29.

Google Scholar

[3] E. on. Grid code for high and extra high voltage, (2003).

Google Scholar

[4] BDEW Technical Guideline, Generating plants connected to medium-voltage network, www. bdew. de, June, (2008).

Google Scholar

[5] Q/GDW 480-2010, Technical rule for distributed resources connected to power grid, State Grid.

Google Scholar

[6] State Grid. Technical rule for the dispersed wind power connected to power grid.

Google Scholar

[7] GB/T 19963-2011, Technical rule for connecting wind farm to power system, Beijing:China Standards Publishing House, (2011).

Google Scholar

[8] DAI Huizhu, CHI Yongning. Study on comparison of wind power connected to power grid in the world, Electric Power, 2012, 45(10): 1-6.

Google Scholar

[9] WANG Weisheng, FAN Gaofeng. Comparison of technical regulations for connecting wind farm to power grid and preliminary research on its integrated control system , Power System Technology, 2007, 31(18):73-76.

Google Scholar

[10] RAO Jianye, XU Xiao-dong. Comparison on technical regulations of China and Other Countries for Grid-connection of wind farms, 2012, 36(8):44-49.

Google Scholar

[11] WANG Jidong, ZHANG Xiaojing, Standard on photovoltaic generation and wind power connected to power grid, Electric Power Automation Equipment, 2011, 31(11):1-6.

Google Scholar

[12] ZHANG Liying, YE Tinglu. Problems and measures of power grid accommodating large scale wind power, 2010, 30(25):1-8.

Google Scholar

[13] ZHANG Yong, GUO Peiyuan. Comparative study of active and reactive power control between wind power codes in China and EU, Power System Protection and Control, 2011, 39(15):141-145.

Google Scholar

[14] XIAO Xiangning. Analysis and Control of Power Quality [M]. Beijing: China Electric Power Press, 2004: 54-58.

Google Scholar

[15] SUN Tao, WANG Weisheng. Voltage fluctuation and flicker caused by wind power generation, 2003, 27(12):63-66.

Google Scholar

[16] Z. Chen. Wind Power in Electrical Distribution Systems. Transactions of China Electrotechnical Society, 2013, 28(5): 1-14.