Study on the Purification Effect of Chlorophytum Comosum on Indoor Formaldehyde

Article Preview

Abstract:

In order to investigate the effect of absorption and purification of indoor formaldehyde by chlorophytum comosum under normal circumstance, chlorophytum comosum is used as the test material and formaldehyde concentration of different closure time is measured by indoor formaldehyde velocimeter. Absorptive capacity of chlorophytum comosum on indoor formaldehyde is analyzed by comparing formaldehyde concentration. The results of experiment show that taking closure time of 24h as an example formaldehyde concentration changes from 0.41 mg/m3 to 0.32 mg/m3 and the removal rate is 21.95% in the room of 15 square meters ,and absorption effect of chlorophytum comosum is good for indoor formaldehyde. Combined with the actual situation chlorophytum comosum can be used in the room place and decorative materials with less formaldehyde content are chosen ,and indoor temperature and humidity remain appropriate to purify indoor formaldehyde by combining with the ventilation method.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

229-232

Citation:

Online since:

October 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] ZhongbiaoWu, WeirongZhao. Indoor air pollution and purification technology[M]. Chemical Industry Press, 2004: 303-332. (In Chinese).

Google Scholar

[2] XiaoliLi. The sources, harms and control of indoor air pollution[J]. Inner Mongolia Environmental Protection, 2009, 21(1): 100-104. (In Chinese).

Google Scholar

[3] JingtaoLi, BaihongPan, YingcuiTian. Overview of research on purification role of indoor plants[J]. Northern horticulture, 2010, 35(1): 101-108. (In Chinese).

Google Scholar

[4] JiaOu, YongXue. Experimental study on purification of ornamental plant to indoor formaldehyde[J]. Resources Inhabitant and Environment, 2008. (In Chinese).

Google Scholar

[5] GuanjiuHu, WeipingYin. Determination method of formaldehyde in interior air[J]. The Administration and Technique of Environmental Monitoring, 2002. (In Chinese).

Google Scholar

[6] DiXu, YanMei, HongjuanNian. Research on Absorptive Capacity of Ornamental Plant Leaves on Formaldehyde[J]. Journal of Anhui Agricultural Sciences, 2009. (In Chinese).

Google Scholar

[7] ZhiliangLiu. Research on Absorptive Capacity of Four Kinds of Potted Ornamental Plants on Formaldehyde and Benzene series[J]. Journal of Heilongjiang Vocational Institute of Ecological Engineering, 2012, 25(1): 45-76. (In Chinese).

Google Scholar