Moving Mode of Wireless Capsule Endoscopy Driven by External Magnetic Field

Article Preview

Abstract:

The existing dynamical systems of wireless capsule endoscopy are studied and analyzed. Based on the shortcomings presented in paper, a novel driving method is proposed. That is driving the wireless capsule endoscopy with three-dimensional orthotropic magnetic field outside the human body, and the resultant magnetic field can be obtained and adjusted through the electric current flowing in three coils orthogonal to each other. This paper focuses on the analysis of complex moving mode of wireless capsule endoscopy, and the result is very important to the design of drive and control circuit.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

318-321

Citation:

Online since:

October 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] J Masseli, JG Albert. Small-Bowel Angiectasia as Detected by Capsule Endoscopy and Treated at Balloon Enteroscopy. Video Journal and Encyclopedia of GI Endoscopy. Vol. 1(2013), pp.276-277.

DOI: 10.1016/s2212-0971(13)70120-1

Google Scholar

[2] C.F. Gao, K.Y. Li, S.P. Zhang. A Novel Approach of Analyzing the Relation between the Inner Heat Source and the Surface Temperature Distribution in Thermal Texture Maps, 27th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Shanghai, China, Sept. 1-4(2005).

DOI: 10.1109/iembs.2005.1616490

Google Scholar

[3] Christina A. Tennyson, Edward J. Ciaccio, Suzanne K. Lewis. A new safe laparoscopic manipulator system with a five bar linkage mechanism and an optical zoom. Video Capsule Endoscopy in Celiac Disease. Vol. 22(2012), pp.747-458.

DOI: 10.1016/j.giec.2012.07.011

Google Scholar

[4] Hongying Liu, Panpan Qiao, Xueli Wu, etc. A smart capsule system of Gastric Occult Blood Detection. Bio-Medical Materials and Engineering. Vol. 24(2014), pp.519-528.

DOI: 10.3233/bme-130838

Google Scholar

[5] J. M. Nicholls, L. L. Poon, K. C. Lee, W. F. Ng, S. T. Lai, et al., Lung pathology of fatal severe acute respiratory syndrome. in Lancet, Vol. 361(2003), pp.1773-1778.

DOI: 10.1016/s0140-6736(03)13413-7

Google Scholar

[6] T. R. Hsu, N. S. Sun, G. G. Chen, Finite element formulation for two dimensional inverse heat conduction analysis, in ASME J. Heat Transfer, Vol. 114(1992), pp.553-557.

DOI: 10.1115/1.2911317

Google Scholar