Numerical Simulation Research on the Internal Flow of a Heat Exchanger

Article Preview

Abstract:

Spiral tube exchanger is one of the most important heat transfer devices among the electric water boilers. In this paper, CFD software is introduced to simulate the process of the flow of the spiral tube exchanger. Cases with different inlet velocities of the cold water have been conducted and results show that, temperature increment of the cold water reaches 38.87 K, 20.21 K and 12.12 K with the inlet velocity of the cold water set as 0.05 m/s, 0.09 m/s and 0.13 m/s respectively.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

200-204

Citation:

Online since:

November 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] R. Chen, H.F. Cui, H. Liu, Analysis on energy conservation certification tests of electric water boilers, Appliance Technology. 10 (2013) 56-57.

Google Scholar

[2] Q. Zhang, J.B. Liu, X.R. Zhao, Partition algorithm of coupled heat transfer for heat exchanger pipe, Sci. Tech. Engng. 10 (2010) 6907-6911.

Google Scholar

[3] S.Q. Pan, A new design for solving the existing problems of electric boiling-water heater, Electrical Appliances. 5 (2013) 40-41.

Google Scholar

[4] C.B. Zhong, C.M. Zhou, T. Sun, Numerical simulation of flow and heat transfer in a clip set type of heat pipe heat exchanger base on fluent, Petro-chemical equipment. 41 (2012) 12-14.

Google Scholar

[5] R. Chen, Analysis on energy conservation of commercial water boilers, Appliance Technology. 4 (2013) 42-43.

Google Scholar

[6] K. Wei, W. Xiao, L. Li, Improvement and energy saving analysis of the existing electric water boiler, Science and Technology Association Forum. 8 (2011) 138-139.

Google Scholar

[7] S.Y. Guo, J.H. Chen, Research progress of fluid-solid coupling application, Sci. and Tech. 18 (2004) 123-126.

Google Scholar

[8] B.J. Lameres, M.H. Nehrir, V. Gerez, A customer-interactive electric water heater demand-side management strategy using fuzzy logic, 1999 IEEE Power-Engineering-Society Winter Meeting. New York, (1999).

DOI: 10.1109/pesw.1999.747494

Google Scholar

[9] J.F. Seara, J. Francisco, J.J. Sieres, Experimental analysis of a domestic electric hot water storage tank. Part II: dynamic mode of operation, Appl. Therm. Eng. 27 (2007) 137-144.

DOI: 10.1016/j.applthermaleng.2006.05.004

Google Scholar

[10] H.J. Zhu, Y.H. Lin and L.H. Xie, FLUENT fluid analysis and the simulation of practical tutorial, Posts and Telecom Press, Beijing, (2010).

Google Scholar

[11] A.K. Kar, Thermal performances of water heaters in series, Appl. Energ. 12 (1995) 521.

Google Scholar

[12] H.W. Guo, A economic analysis of the heat exchanger performance, Journal of Chemical Industry and Engineering. 23 (2002) 19-20.

Google Scholar

[13] J.S. Shi, J. Han, Economical analysis of solar energy boiled tank, Energy Conservation Technology. 4 (2005) 372-374.

Google Scholar

[14] X.Z. Zhang, M. Li, J.W. Zhu, X.Y. Liu, Energy-efficient electric boilers, Science in 24 hours. 6 (2007) 25.

Google Scholar