Detection Experiment Research of Harmonic Current for Single-Phase Active Power Filter

Article Preview

Abstract:

In order to solve the problem of detecting harmonic and reactive currents of single-phase APF, the paper gives a detection method for real time harmonic current and reactive current. In the paper, it makes use of some characteristics of triangle function, and calculates the amplitude of active and reactive component from load current. Then the DC component can be extracted by using a low-pass filter, namely the required active component and reactive component. This paper analyzes the characteristics of two kinds of low pass filter, and selects the superior performance moving average filter for experiment. The paper introduces the design of the software and hardware process. The circuit configuration of the proposed approach used in the single-phase system is simple, its dynamic response speed is fast and its detection precision is high. The result of the experiment shows that the proposed approach is feasible and valid.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

297-302

Citation:

Online since:

December 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] WangZhaoan, YangJun, LiuJinjun. Harmonic suppression and reactive power compensation [M].Beijing:Machinery Industry Press,2006:12-49.

Google Scholar

[2] Akagi H,Kanazawa Y,Nabae A.Instantaneous Reactive PowerCompensators Compensators Comprising Switching Devices Without Energy Storage Components[J].IEEE Trans.On Industry Application,1983,20(3):625-630.

DOI: 10.1109/tia.1984.4504460

Google Scholar

[3] Jiang Bin,Yan Gangfeng,Zhao Guangzhou.A new method for real-time detection harmonics and reactive currents in single-phase circuit[J].Automation of Electric Power Systems,2000,22(4):35-39.

Google Scholar

[4] Geng Yunling,Wang Qun.Real time detection approach of harmonic and reactive currents for single-phase circuit[J].Journal of National University of Defense Technology,2000,22(4):111-115.

Google Scholar

[5] Zhao Yang,Xu Chaoyang,WuSimin,etal.Application of SDFT algorithm in single phase shunt active power filter[J].Power Electronics,2013,47(2):101-103.

Google Scholar

[6] Guo Shuai. Research on three-phase and three-wire parallel active power filter[D]. Harbin: Harbin Institute of Technology.

Google Scholar

[7] Zhang Xu,Huang Xixia,Kong Xiangpin,etal.Application of phase locked frequency multiplier circuit in the voltage signal DSP data acquisition[J].Journal of Power Supply,2012,(5):32-36.

Google Scholar