Sensitive Structure Optimization and Verification of Cantilever Beam Gyroscope

Article Preview

Abstract:

In order to enhance the measurement accuracy of cantilever vibration gyroscope, we modify the sensitive structure of the cantilever vibration gyroscope and develop a verifiable method. Firstly, analyzing the cause of influencing the measuring accuracy and the piezoelectric plate coupling structure of the original cantilever vibration gyroscope, we propose a new piezoelectric plate coupling structure. Secondly, in order to prove engineering feasibility of new structure, we use ANSYS software to simulate the new structure with 50, 60, 100 mm cantilevers. Simulation and experiments show that the average sensitivity of the new structure gyroscope increases by 8.64%. According to these results, we can conclude that the improved cantilever vibration gyroscope can be used in engineering application.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

480-484

Citation:

Online since:

December 2014

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] H. Xie and G. K. Fedder. Integrated Microelectromechanical Gyroscopes. Journal of Aerospace Engineering, 2003, 16(2): 65-75.

DOI: 10.1061/(asce)0893-1321(2003)16:2(65)

Google Scholar

[2] Greiff P, Boxenhorn B, King T, et al. Silicon monolithic micromechanical gyroscope[J]. Solid-State sensors and actuators, 1991, 24-27: 966-968.

DOI: 10.1109/sensor.1991.149051

Google Scholar

[3] Bernstein, CHO J, King S, et al. A micro-machined comb-drive tuning fork rate gyroscope[C]. Proceedings of the IEEE, 1993: 143-148.

DOI: 10.1109/memsys.1993.296932

Google Scholar

[4] Juneau T, Pisano A P, James H S, et al. Dual axis operation of a micro-machined rate gyroscope. Solid State Sensors and Actuators, 1997: 833-886.

DOI: 10.1109/sensor.1997.635243

Google Scholar

[5] Stress on the shape of doubly supported surface-Micro-machined Beams. Journal of Micro-electromechanical Systems, 2000, 9(3).

Google Scholar

[6] Spearing. S. M. Material issues in Micro-electromechanical Systems. Auto Master, (2000).

Google Scholar

[7] LIU Y, LU Y L, ZENG L L, et al. Dynamic characteristic analysis and machining error study based on solid vibration beam rate sensor [J]. IEEE Advanced Materials Research, 2011, 148-149: 529-534.

DOI: 10.4028/www.scientific.net/amr.148-149.529

Google Scholar

[8] LIU Y, LU Y L, ZENG L L, et al. Drift error compensation algorithm for fiber optic gyro base on T-S fuzzy modeling[J]. Journal of Chongqing University, 2010, 30(2): 60-65.

Google Scholar

[9] LIU Y, Solid-state Vibration Gyroscope and Navigation Technology[M]. Beijing: China Aerospace Press, 2010. (in Chinese).

Google Scholar