Research on the Relationship between SPT and the Ultimate Vertical Bearing Capacity of Jacked Pile in Shenyang District

Abstract:

Article Preview

Though the wide applications of jacked pile in engineering in Shenyang district, the problem is also exist in engineering for the capacity of the jacked pile is hard to account. The relationship between the standard penetration test and the ultimate vertical bearing capacity of jacked pile is established in this paper; also an empirical formula is put forward for calculating the ultimate vertical bearing capacity of the jacked pile in this district with blow count of standard penetration test (SPT). The engineering examples indicated that the empirical formula is feasible because the calculating bearing capacity of the silent pipe pile is coincided with the static load tests. The calculated results satisfy the engineering requirement andt can be concluded that the method is also convenient to choose the diameter and length of the pile during the initial stage of design.

Info:

Periodical:

Edited by:

Dongye Sun, Wen-Pei Sung and Ran Chen

Pages:

3308-3311

DOI:

10.4028/www.scientific.net/AMM.71-78.3308

Citation:

X. Ruan and R. Y. Zuo, "Research on the Relationship between SPT and the Ultimate Vertical Bearing Capacity of Jacked Pile in Shenyang District", Applied Mechanics and Materials, Vols. 71-78, pp. 3308-3311, 2011

Online since:

July 2011

Export:

Price:

$35.00