The Research Progress of Earth to Air Heat Exchanger: A Review

Article Preview

Abstract:

As a renewable and energy-saving technology, the earth to air heat exchanger has great advantages over the traditional thermal technologies both in initial investment and operation cost. This paper aims to review the research progress of EAHE in the world in view of numerical models and experiments, in which the EAHE needs to be further studied in the further.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

211-214

Citation:

Online since:

February 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Trilok Singh Bisoniya, Anil Kumar, Prashant Baredar, Experimental and analytical studies of earth–air heat exchanger (EAHE) systems in India: A review, J. Renewable and Sustainable Energy Reviews 19(2013) 238–246.

DOI: 10.1016/j.rser.2012.11.023

Google Scholar

[2] Jens Pfafferott, Evaluation of earth-to-air heat exchangers with a standardized method to calculate energy efficiency , J. Energy and Buildings. 35 (2003) 971–983.

DOI: 10.1016/s0378-7788(03)00055-0

Google Scholar

[3] D'Accadia MD, de Rossi F, Thermo-economic optimization of a refrigeration plant , J. International Journal of Refrigeration. 21(1998) 42–54.

Google Scholar

[4] Tzaferis A, LIParakis D, Santamouris M, Argiriou A, Analysis of the accuracy and sensitivity of eight models to predict the performance of earth to air heat exchanger, J. Energy and Buildings. 18(1992) 35–43.

DOI: 10.1016/0378-7788(92)90049-m

Google Scholar

[5] Mihalakakou G, Santamouris M, Asimakopoutos D, Modeling the thermal performance of the earth to air heat exchanger, J. Solar Energy 53(1994) 301–5.

DOI: 10.1016/0038-092x(94)90636-x

Google Scholar

[6] Bojic M, Trifunovic N, Papadakis G, Kyritsis S, Numerical simulation, technical and economic evolution of air to earth heat exchanger coupled to building, J. Energy 22(1997) 1151–8.

DOI: 10.1016/s0360-5442(97)00055-8

Google Scholar

[7] Wu H, Wang S, Zhu D, Modeling and evaluation of cooling capacity of earth–air–pipe systems, J. Energy Conversion and Management 48(2007) 1462–71.

DOI: 10.1016/j.enconman.2006.12.021

Google Scholar

[8] Aslam Bhutta Muhammad Mahmood, Hayat Nasir, Hassan Bashir Muham-mad, Rais Khan Ahmer, Naveed Ahmad Kanwar, Sarfaraz Khan, CFD applica-tions in various heat exchangers design: a review, J. Applied Thermal Engineering 32(2012) 1–12.

DOI: 10.1016/j.applthermaleng.2011.09.001

Google Scholar

[9] Abdelkrim Sehli, Abdelhafid Hasni, Mohammed Tamali, The potential of earth–air heat exchangers for low energy cooling of buildings in South Algeria, J. Energy Procedia 18(2012) 496–506.

DOI: 10.1016/j.egypro.2012.05.061

Google Scholar

[10] Cucumo M, Cucumo S, Montoro L, Vulcano A, A one-dimensional transient analytical model for earth-to-air heat exchangers, taking into account condensation phenomena and thermal perturbation from the upper free surface as well as around the buried pipes, J. Heat and Mass Transfer 51(2008).

DOI: 10.1016/j.ijheatmasstransfer.2007.05.006

Google Scholar

[11] Badescu V, Simple and accurate model for the ground heat exchanger of a passive house, J. Renewable Energy 32(2007) 845–55.

DOI: 10.1016/j.renene.2006.03.004

Google Scholar

[12] Kabashnikov VP, Danilevskii LN, Nekrasov VP, Vityaz IP, Analytical and numerical investigation of the characteristics of a soil heat exchanger for ventilation systems, J. International Journal of Heat and Mass Transfer 45(2002) 2407–18.

DOI: 10.1016/s0017-9310(01)00319-2

Google Scholar

[13] Tittelein P, Achard G, Wurtz E, Modeling earth to air heat exchanger behavior with the convolutive response factor methods, J. Applied Energy 86 (2009) 1683–91.

DOI: 10.1016/j.apenergy.2009.02.010

Google Scholar

[14] Xia Chunhai, Zhou Xiang, Ouyang Qin, Zhu Yingxin, Numerical simulation and analysis of underground duct system, J. Acta Energiae Solaris Sinica9 (2006) 923-928.

Google Scholar

[15] Song Ling, Zhu Yingxin, Simulation study on cooling potential of multi-tube earth-air tunnels, J. HV&AC 9 (2009) 66-69.

Google Scholar

[16] Onder Ozgener, Leyla Ozgener, Exergetic assessment of EAHEs for building heating in Turkey: A greenhouse case study, J. Energy Policy 38(2010) 5141-5150.

DOI: 10.1016/j.enpol.2010.04.047

Google Scholar

[17] Leyla Ozgener, Onder Ozgener, Exergetic performance test of an underground air tunnel system for greenhouse heating, J. Energy 35(2010) 4079-4085.

DOI: 10.1016/j.energy.2010.06.020

Google Scholar

[18] Vikas Bansal, Rohit Misra, Ghanshyam Das Agarwal, Jyotirmay Mathur, Transient effect of soil thermal conductivity and duration of operation on performance of Earth Air Tunnel Heat Exchanger, J. Applied Energy 103(2013) 1-11.

DOI: 10.1016/j.apenergy.2012.10.014

Google Scholar

[19] Rohit Misra, Vikas Bansal, Ghanshyam Das Agarwal, Jyotirmay Mathur, Tarun Aseri, Transient analysis based determination of derating factor for earth air tunnel heat exchanger in summer, J. Energy and Buildings 58(2013)103-110.

DOI: 10.1016/j.enbuild.2012.11.001

Google Scholar