Research on Relay Protection of Distribution Network System with Distributed Generation

Article Preview

Abstract:

Introduce the current development of distributed generation, the structure and protection configuration of existing distribution network, and the fault current insert of different kinds of distributed generation was introduced. Through the distribution network in different positions to join distributed generation, the influence of the join of distributed generation on the existing protection of distribution network was analyzed, which included the serious interference to the sensitivity and selectivity of the original protection, the refusal of line protection, the action error of non- fault line protection. The influence of distributed generation on automatic reclosing, and the effect between fuses was discussed, to some extent, and base on the discussion some appropriate countermeasures are proposed.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

670-674

Citation:

Online since:

February 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] S.M. Brahma, A.A. Girgis. Microprocessor-based reclosing to coordinate fuse and recloser in a system with high penetration of distributed generation[C]. IEEE 2002 Power Engineering Society Winter Meeting, 2002, 1: 453-458.

DOI: 10.1109/pesw.2002.985041

Google Scholar

[2] M.I. Marei, E.F. El-Saadany, M.M.A. Salama. An intelligent control for the DG interface to mitigate voltage flicker[C]. IEEE Eighteenth Annual Applied Power Electronics Conference and Exposition, 2003, 1: 179-183.

DOI: 10.1109/apec.2003.1179211

Google Scholar

[3] A. Bhowmik, A. Maitra, S.M. Halpin, J.E. Schatz. Determination of allowable penetration levels of distributed generation resources based on harmonic limit considerations [J]. IEEE Transactions on Power Delivery, 2003, 18(2): 619-624.

DOI: 10.1109/tpwrd.2003.810494

Google Scholar

[4] H.P. Kan K.T. Chau,M. Cheng. Development of doubly salient permanent magnet motor flywheel energy storage for building integrated photovoltaic system[J]. Proceeding of IEEE Applied Power Electronic Conference and Exposition, 2001, 1: 314-320.

DOI: 10.1109/apec.2001.911666

Google Scholar

[5] Hydro-Québec TransÉnergie Technologies. SimPowerSystems for Use with Simulink,User's Guide[M]. The MathWorks, Inc. (2002).

Google Scholar

[6] J.C. Gomez, M.M. Morcos. Coordinating overcurrent protection and voltage sag in distributed generation systems[J]. IEEE Power Engineering Review, 2002, 22(2): 16-19.

DOI: 10.1109/39.981336

Google Scholar

[7] K. Maki,S. Repo, P. Jarventausta. Effect of wind power based distributed generation on protection of distribution network[C]. Eighth IEEE International Conference on Developments in Power System Protection, 2004, 1: 327-330.

DOI: 10.1049/cp:20040129

Google Scholar