The Indoor Radon Concentration Measurement and Analysis in a University and its Adjacent Areas

Article Preview

Abstract:

Radon is a radioactive gas, high concentrations of radon in the environment can cause lung cancer, leukemia and other diseases. In this paper, indoor radon concentration in different places were measured and analyzed by using the RAD-7 radon monitor in a university and its adjacent areas. On-site measurements show that within 24 hours the indoor radon concentration versus time has certain regularity, different interior architectural decoration materials has a certain influence on the radon concentration, the radon concentrations in long confined spaces are significantly higher than those places frequently ventilated, floor height and ventilation conditions have a greater impact on the radon concentration. This research can provide a reference for future prevention and control of radon hazards.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

512-515

Citation:

Online since:

March 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Yeqiang Li. The investigation and estimation of radon concentration in air in main districts of Chongqing City. Chengdu: Chengdu University of Technology, 2010(In Chinese).

Google Scholar

[2] Weixing Wang, Leiming Wang, Jigen Lu, et al. Harm of radon in underground-buildings of city and its protection. Journal of Safety and Environment, Beijing, Vol. 6 (Jul. 2008), pp.160-163(In Chinese).

Google Scholar

[3] Bochicchio F, Antignani S, Venoso G, et al. Quantitative evaluation of the lung cancer deaths attributable to residential radon: A simple method and results for all the 21 Italian Regions. England, Radiation Measurements, Vol. 50 (2013).

DOI: 10.1016/j.radmeas.2012.09.011

Google Scholar

[4] Jingshu Qin, Pinghua Dang, Guang Zhou. The study on indoor environmental pollution's damage. Chongqing building, Chongqing, Vol. 3 (2004), pp.55-57(In Chinese).

Google Scholar

[5] Jian Ge. Nuclear radiation measure apply in the ground exploration. Chengdu: Chengdu University of Technology, 2008(In Chinese).

Google Scholar

[6] Code for Indoor Environmental Pollution Control of Civil Building Engineering (GB50325-2010). Beijing: China Planning Press, 2013(In Chinese).

Google Scholar

[7] Kokotti Helmi, Keskikuru Timo, Kalliokoski Pentti. Radon mitigation with pressure controlled mechanical ventilation. England, Building and Environment, Vol. 29(1994), pp.387-392.

DOI: 10.1016/0360-1323(94)90039-6

Google Scholar

[8] Xiaoyan Li. A study of radon level and its health effcts to people in undergorund buildings in China. Guiyang : Institute of Geochemisty, Chinese Academy of Seiences, 2005(In Chinese).

Google Scholar