Experimental Study of Seismic Performance of Precast Fabricated Integration Shear Wall

Article Preview

Abstract:

A new method to infill the opening in the precast fabricated concrete shear wall was applied in China. In this paper, three geometrically identical precast fabricated shear wall specimens were constructed and tested under constant axial load and quasi-static cyclic lateral loading. The only difference among three specimens was the methods to infill the opening in the middle, the methods were respectively integration infill, masonry infill and without infill. The hysteretic curves, the skeleton curves, the failure process, the strain variation of reinforcement, the stiffness, the ductility and energy-dissipating capacity were obtained. The results and analysis showed that integration shear wall owns good seismic performance. Its bearing capacity, stiffness, energy-dissipating capacity are excellent while ductility is relatively poor. Masonry infilled wall and wall without infill also own good seismic performance.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

105-112

Citation:

Online since:

March 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Z.X. Guo, Y.B. Wu and X.Q. Huang: Journal of Earthquake Engineering and Engineering Vibration. Vol. 28. No. 6 (2008), pp.172-177 (in Chinese).

Google Scholar

[2] E. Canbay: Contribution of Reinforced Concrete Infills to the Seismic Behavior of Structural Systems, A Doctor of Philosophy Thesis in Civil Engineering, Middle East Technical University, Ankara (2001).

Google Scholar

[3] R.E. Klingner and V.V. Bertero: Proc. of the ASCE, Vol. 104. No. ST6 (1978), pp.973-989.

Google Scholar

[4] M. Saatcioglu: Seismic Assessment and Rehabilitation of Existing Buildings, edited by S. Tanvir Wasti and Guney Ozcebe, Nato Science Series, IV. Earth and Environmental Series, Vol. 29. (2003), pp.457-486.

DOI: 10.1007/978-94-010-0021-5

Google Scholar

[5] S. Altin, U. Ersoy and T. Tankut: Journal of Structural Engineering, Vol. 118. No. 8 (1992), pp.2133-2150.

Google Scholar

[6] H.B. Jiang, H.S. Zhang and W.Q. Liu: Journal of Harbin Institute of Technology. Vol. 43. No. 4 (2011), pp.28-31 (in Chinese).

Google Scholar

[7] JGJ 101-96 Specification of Testing Methods for Earthquake-Resistant Building, , Specifications (1996). (in Chinese).

Google Scholar

[8] C.R. Yang, X.G. Zhong and D.H. Liu: China Civil Engineering Journal. Vol. 21(1988), pp.30-39 (in Chinese).

Google Scholar

[9] JGJ 3-2010 Technical Specification for Concrete Structures of Tall Building, , Specifications (2010). (in Chinese).