Abstract:

A contrast investigation of the seismic behavior of unreinforced masonry walls with window openings strengthened with Carbon Fibre Reinforced Polymer (CFRP) sheets and sprayed Glass Fibre Reinforced Polymer (GFRP) is presented. Three wall specimens in the scale of 1/2 were tested by the horizontal cyclic loading combined with constant gravity loads. The seismic strengthening effects by two different FRP retrofitting schemes are compared in aspect of the hysteresis response, deterioration of rigidity and ability of energy dissipation. The experimental results indicate that the increasing degree of the improvement of seismic behavior of the SGFRP-strengthened wall are significantly superior to that of the wall strengthened with epoxy-based CFRP; and the overcoat of sprayed GFRP can bond tightly and work well together with the masonry to play a critical role in earthquake resistance.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

113-117

Citation:

Online since:

March 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Yayong Wang. The building damage Revelation of Wenchuan earthquake. 2008 Proceedings of Earthquake Prevention and Disaster Reduction Forum in Chinese. Zhengzhou, (2008) 9: 63-74.

Google Scholar

[2] Fangfei Ye, Xianglin Gu, Weiping Zhang, Ouyang Yu. Finite element analysis on shearing behavior of brick walls strengthened with CFRP plates. Structural Engineers, 21(3), (2005), pp.19-24.

Google Scholar

[3] Huifang Lu, Qian Gu, Chengfang Sun, Shaomin Peng. Experimental study on seismic behavior of brick wall with a window reinforced by carbon fiber sheet. Journal of Wuhan University of Technology, ( 2005), 27(2): pp.28-31.

Google Scholar

[4] Xingang Zhou, Changqing WEI, Lieping Ye. Mechanical behavior of masonry walls strengthened with CFRP. Engineering Mechanics, 25(6) (2008),: pp.51-59.

Google Scholar

[5] H. K. Lee, L. R. Hausmann. Structural repair and strengthening of damaged RC beams with sprayed FRP. Composite Structures, 63, (2004), pp.201-209.

DOI: 10.1016/s0263-8223(03)00156-9

Google Scholar

[6] A. J. Boyd, N. F. Liang, P. S. Green and K. Lammert. Sprayed FRP Repair of Simulated Impact in Prestressed Concrete Girders. Construction and Building materials, (2008), 22(3): 411-416.

DOI: 10.1016/j.conbuildmat.2006.05.061

Google Scholar

[7] Zhi Zhang, Qian Gu, Kaicheng Huo. Experimental investigations of masonry walls strengthened by SGFRP. Journal of Wuhan University of Technology, (2010), 32(13), pp.58-61.

Google Scholar

[8] Feng Li. Experimental study and finite element analysis on masonry wall seismic strengthened by SGFRP. Wuhan: Wuhan University of Technology, (2009).

Google Scholar

[9] Qian. Gu, Bo. Peng, F. Li and Z. Zhang. In-plane Seismic Strengthening of Masonry Walls with Sprayed Glass Fiber Reinforced Polymer. Proceedings of the 12th Biennial ASCE Aerospace Division International Conference on Engineering, Science, Construction, and Operations in Challenging Environments, Hawaii, Mar. 14-17, (2010).

DOI: 10.1061/41096(366)267

Google Scholar

[10] JGJ 101-96,Specification of testing methods for earthquake resistant building.

Google Scholar