Application of Sorptive Building Materials Reducing Indoor Air Pollution for Improving Indoor Air Quality

Article Preview

Abstract:

In order to improve indoor air quality, the interest in and the use of sorptive building materials that decrease the concentration of an indoor air pollutant have increased. The use of sorptive building materials is one way to decrease the concentration of an indoor pollutant that can adversely affect human health. In this study, we evaluated the effects of sorptive building materials applied to a wall on the decrease in the concentration of toluene emitted from the flooring. We also examined how the air exchange rate of the room, the loading factor of the sorptive materials, and the mass transfer coefficient influenced the sorptive performance; these effects were well reproduced experimentally with computational fluid dynamics (CFD) simulations. The results show that sorptive building materials have a fairly strong effect on the decrease in toluene concentrations in rooms and that this effect can be expected in real-world scenarios.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

358-361

Citation:

Online since:

April 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Ataka Y, Kato S, Murakami S, Zhu Q, Ito K and Yokota T: Study of effect of adsorptive building material on formaldehyde concentrations: development of measuring methods and modeling of adsorption phenomena: Indoor Air 2004; 14(8): 51-64.

DOI: 10.1111/j.1600-0668.2004.00316.x

Google Scholar

[2] R. Reiser, A. Meile, C. Hofer and R. Knutti: Proceedings of the Conference on Indoor Air 2002; 1004-1009.

Google Scholar

[3] J. Seo, S. Kato, Ataka and S. Nagao: Measurement and CFD analysis on decteasing effect of toluene concentration with activated carbon and adsorptive building material: Proceedings of Healthy building 2006; 5: 101-106.

Google Scholar

[4] H. Kim, K. Song, and Y. Lee: A study on the Mock up test for reduction of HCHO using the functional gypsum board: Korea Journal of Air-Conditioning and Refrigeration Engineering 2008; 20(12): 814-819.

Google Scholar

[5] Bornehag CG et al.: The Association Between Asthma and Allergic Symptoms in Children and Phthalates in House Dust; A Nested Case Control Study: Environmental Healthy Perspectives 2004; 112(14): 1393-1397.

DOI: 10.1289/ehp.7187

Google Scholar

[6] J. Seo, S. Kato, Y. Ataka, and S. Chino: Performance test for evaluating the reduction of VOCs in rooms and evaluating the lifetime of sorptive building materials: Building Environment 2009; 44(1): 207–215.

DOI: 10.1016/j.buildenv.2008.02.013

Google Scholar