Research on Jing-Jin-Tang Power Grid Coordinated Control Strategy

Article Preview

Abstract:

The disadvantage of Beijing-Tianjin-Tangshan power grid operation control mode is that the control effect is poorer and the spare capacity demand is big, this paper puts forward a new coordinated control strategy. First of all, this paper describes the relationship between the load, frequency, the output of generating unit, the tie line power and the area control error relationship of the whole power grid, according to the regional automatic generation control performance assessment criteria, concludes the characteristics of regional unit adjustment. This paper analyzes the contradiction between them, and then proposes a coordinated control strategy between the Beijing-Tangshan power grid and Tianjin power grid. The case simulation results prove the superiority and feasibility of the new coordinated control strategy. Compared with the original, the new strategy reduces the volatility of the unit, shortens the recovery time of frequency, and has a certain practical significance.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1306-1310

Citation:

Online since:

October 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] LIU Zhen-ya. Electric Power and Energy in China [M]. Beijing: China Electric Power Press, (2012).

Google Scholar

[2] IBRAHEEN, Kumar P, Kothari D P. Recent philosophies of automatic generation control strategies in power systems [J]. IEEE Trans on Power Systems, 2005, 20(1): 246-357.

DOI: 10.1109/tpwrs.2004.840438

Google Scholar

[3] JALEELI N, et al. Understanding automatic generation control [J]. IEEE Trans on Power Systems, 1992, 7(3): 1106-1122.

DOI: 10.1109/59.207324

Google Scholar

[4] Performance standard training document [EB/OL]. [2009-02-02]. http: /www. nerc. com.

Google Scholar

[5] Policy1—generation control and performance [EB/OL]. [2009-02-02]. http: /www. nerc. com.

Google Scholar

[6] SHANG Xue-wei, LI Li-xin, ZHUO Jun-feng, et al. Improvement of Strategies of AGC in North China Power Grid After UHVAC Pilot Project Operation[J]. Power System Technology, 2010, 34(9): 31-34.

DOI: 10.1109/powercon.2010.5666661

Google Scholar

[7] YAN Wei, ZHAO Rui-feng, ZHAO Zhen et al. Review on control strategies in automatic generation control [J]. Power System Protection and Control, 2013, 41(8): 149-155.

Google Scholar

[8] TAN Tao, JIANG Jie, HE Qian et al. Research on provincial power grid AGC control strategy [J]. Power System Protection and Control, 2011, 39(16): 63-66.

Google Scholar

[9] ZHAO Chuan, ZHU Tiao, YE Hua. Research and realization of coordinated automatic generation control based on multi-control zone [J]. Power System Protection and Control, 2014, 42(16): 46-51.

Google Scholar