Non-Conventional Technologies for the Manufacturing Systems Use in Biological Wastewater Treatment Process

Article Preview

Abstract:

Manufacture of wastewater treatment technologies is an important issue due to the complexity of design parameters and performance. Biological wastewater treatment is a process in which the intensity of oxygen transfer into water is an issue that has been extensively studied but yet insufficiently resolved. The present paper aims to describe an aeration system developed by the author in the laboratory by means of non-conventional technologies, and subsequently implemented in refinery wastewater treatment plants. The aeration system takes the form of modules, which are equipped with a new type of membrane. The analysis of the system performance revealed that oxygen transfer was 62%, specific adsorption of oxygen was 37 % and the specific oxygen transfer was 7%/m. The advantages of this new system are as follows: compared to existing technologies there is a higher rate of oxygen transfer into water; longer life; there are no dead zones in the basin as a result of their location; possibility of operating on separate sections.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1573-1578

Citation:

Online since:

November 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] C. Panaitescu, I. Onutu, Monitoring the quality of the sludge resulted from domestic wastewater treatment plants and the identification of risk factors, EEJM. 12 (2013) 351-358.

DOI: 10.30638/eemj.2013.043

Google Scholar

[2] C. Panaitescu, R. Bucuroiu, Study on the composition of municipal waste in urban areas of Prahova county , EEJM. 13 (2014) 1567-1571.

DOI: 10.30638/eemj.2014.173

Google Scholar

[3] C. Panaitescu, C. Popescu et al, Information management for monitoring surface water quality - case study: Ploiesti, Romania, Information management in the modern organizations: trends & solutions, in the proceedings of the 9th International-Business-Information-Management-Association Conference (IBIMA), Marrakech, Morroco, 2008, p.1100.

Google Scholar

[4] C. Stratula, C. Panaitescu, A. Lungu, A. Pana, Revue Chimie, 56 (2005) 677-671.

Google Scholar

[5] C. Patrascioiu, C. Panaitescu, N. Paraschiv, Control valves – Modeling and Simulation, in the procedings of the 5th WSEAS International Conference on Dynamical Systems and Control, LaLaguna, Spain, 2009, pp.63-68.

Google Scholar

[6] A. Gilpin, Dictionary of Environment and Development, Chester and New York, John Wiley and Sons, (1996).

Google Scholar

[7] J. Smith, J. and J. Clarkson, Design concept modeling to improve reliability, J. Eng. Design, 16 (2005) 421–476.

Google Scholar

[8] V. Rojanschi, T. Ognean, The book operator stations and sewage treatment (in Romanian), Tehnică Publishing House, București, (1989).

Google Scholar

[9] A.R. Rao, Predication of reaeration rate in square, stirrers tanks, Journal of Environmental. Engineering. 133 (1999) 411 – 418.

Google Scholar

[10] A.R. Rao, B. Kumar, Neural modeling of square surface aerators, Journal of Environmental. Engineering. 125 (2007) 215-223.

Google Scholar

[11] C.E. Boyd, Pond water aeration systems, Aquacultural Engineering. 18 (1998) 9-40.

DOI: 10.1016/s0144-8609(98)00019-3

Google Scholar

[12] ** ASCE Manual (18-96), Standard Guidelines for In-Process Oxygen Transfer Testing, available at http: /www. ascelibrary. org/doi/book, accessed: 12. 02. (2015).

Google Scholar

[13] R. Artusi , P. Verderio, E. Marubini, Bravais-Pearson and Spearman correlation coefficients: meaning, test of hypothesis and confidence interval, Int J Biol Markers, 17 (2002) 148-151.

DOI: 10.1177/172460080201700213

Google Scholar

[14] J.I. Piovani, The historical construction of correlation as a conceptual and operative instrument for empirical research. Quality & Quantity. 42 (2008) 757–777.

DOI: 10.1007/s11135-006-9066-y

Google Scholar