Stress Analysis in the Combination of Footplate and Caisson Foundation

Article Preview

Abstract:

Currently, the combined footplate-caisson foundation has been used for some projects. This type of foundation is one of the chosen low cost foundations for the structure supporting medium load when the bearing capacity of conventional foundation is not sufficient. The inserted caisson underneath the footing enables to increase its performance; has a better bearing capacity and lower settlement. Unfortunately, the theoretical basic regarding this foundation is not available so that the design tends to use a conservative approach. For this reason, the study on footplate-caisson foundation is essential to obtain the information of its performances. In this study, the combined footplate-caisson was numerically modelled in plane-strain condition as a foundation resting on clay. The footplate was modelled in the depth variation of 0.75 m up to 1.5 m in fixed width of 1.5 m x 1.5 m; whereas the caisson was modelled in depth variation of 0.75 up to 4.5 m in fixed diameter of 1.0 m. The properties of soil and foundation are presented in the paper. The applied load on the model was varied from 60 kPa up to 1000 kPa. The result of the study indicates that the presence of caisson contributes to the decrease in contact pressure in footplate. The percentage of the contribution depends on the dimension of each element and the depth of caisson.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

89-93

Citation:

Online since:

July 2016

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2016 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Der-Guey Lin and Zheng-Yi Feng, A Numerical Study Of Piled Raft Foundations, Journal of the Chinese Institute of Engineers, (2006).

Google Scholar

[2] H.G. Poulos, J.C. Small, and H. Chow, Pile Raft Foundations to Tall Buildings, Geotechnical Engineering Journal of the SEAGS & AGSSEA, (2011).

Google Scholar

[3] Jean-Louis Briaud et al, ISSMGE Combined Pile-Raft Fundation Guideline, Germany Technische Universitat Darmstadt, (2013).

Google Scholar

[4] Virgo Erlando Purba and Novdin M. Sianturi, Study Selection The Caison As An Alternative Design Foundation, Rancang Sipil Journal , (2013).

Google Scholar

[5] Wahyu Adi Sulistyo et al, Study Effect of Static and Dynamic Imposition Of Shallow Foundations with Pillar Reinforcement of Composition Optimal Buis Concrete Using Waste Materials in Bangkalan (Modeling Laboratory), ITS Journal, (2012).

Google Scholar