Corrosion Diagnosis and Mechanism of Boiler Water-Cooled Wall Tubes in Alkaline Environment

Article Preview

Abstract:

Failure analysis was carried out to find out the causes of burst on water-cooled wall tubes elbow for circulating fluidized bed (CFB) boiler.Through macro-observations, chemical composition analysis, macro structure observations,grain size measurements and water quality examinations, it can conclude that the high pH value of boiler water at the fire-facing side of weld dense phase zone will lead to alkali concentration that will cause alkali corrosion. The existence of residual stress in elbow under strong alkaline environment will cause alkali stress corrosion. Research results show that the tube failure is caused by both alkali corrosion and alkali stress corrosion. Strengthen water quality monitoring and elimination of stress can effectively prevent the alkali corrosion and alkali stress corrosion.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

488-492

Citation:

Online since:

September 2016

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2017 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] XU Hong. An Investigation on the Mechanism of Alkali Gouging Failure in Water-Wall-Tubes for a High-Pressure Drum Boiler [J]. Proceedings of the CSEE, 2003, 23(2): 183-187.

Google Scholar

[2] SUN Lianqi. Wearing mode and Lifespan Evaluation of Water Wall of Circulating Fluidized Bed Boiler [J]. China Special Equipment Safety, 2015, 30(8): 37-41.

Google Scholar

[3] XU Hongfei, XUE Yuejun, ZHENG Ziqin et al. Corrosion failure analysis on water-cooled wall tubes of power station [J]. Ordnance Material Science and Engineering, 2013, 36(2): 119-122.

Google Scholar

[4] LU Liming, Lin Kaiming, Huang Hui et al. Analysis on the Corrosion and Leakage Accident of Boiler Water Wall Pipe [J]. Petrochemical Safety and Environmental Protection Technology, 2014, 30(4): 43-44.

Google Scholar

[5] XU Wei Li Wurong. Analysis of the Causes of Circulating Fluidized Bed Boiler Water Wall Leakage [J]. China Special Equipment Safety, 2015(S1): 72-80.

Google Scholar

[6] WANG Yian. Cracking Analysis of Gas Equilibria Pipeline in C-4 Unit [J]. China Special Equipment Safety, 2015(S1): 134-136.

Google Scholar

[7] GB/T 30579-2014 Damage modes identification for pressure equipments [S]: 20, 36, 37.

Google Scholar

[8] TSG G7002-2015 Boiler Periodical Inspection Regulation [S]: 5.

Google Scholar