Measurement and Characteristics Analysis of In Situ Stress in Expanding Area of Tao’er Coal Mine

Abstract:

Article Preview

In order to fully understand and correctly evaluate the stability of overlying strata and surrounding rock, in-situ stress of south main roadway, north main roadway and bypass in shaft station of expanding area, Tao’er coal mine was tested by KX-81-style triaxial stress gauge of hollow inclusion. The test results show that tectonic stress is main in in-situ stress of expanding area, Tao’er coal mine, horizontal principal stress is westeast distribution, 31.13-27.42MPa size, 27.42°-275° direction. Each stress state is not identical, vertical stress is basically slightly less than the weight of the rock covering on unit area. Application of measuring principle of in-situ stress and analysis of field measurement provide a reliable basis for roadway support design and parameters optimization in expanding area of Tao’er coal mine, ensure safety and smooth construction of roadway.

Info:

Periodical:

Edited by:

Xuejun Zhou

Pages:

1732-1735

DOI:

10.4028/www.scientific.net/AMM.90-93.1732

Citation:

H. J. He et al., "Measurement and Characteristics Analysis of In Situ Stress in Expanding Area of Tao’er Coal Mine", Applied Mechanics and Materials, Vols. 90-93, pp. 1732-1735, 2011

Online since:

September 2011

Export:

Price:

$35.00

In order to see related information, you need to Login.