Analysis on Fracture Causes of Condensate Water Pump Shaft

Article Preview

Abstract:

Failure causes on a condensate pump shaft were discussed by means of macroscopic observation, chemical composition analysis, metallurgical microstructure inspection, mechanical property tests and stress analysis. The experimental results showed that the improper material with disqualified chemical composition, improper microstructure and poor mechanical properties acted as inherent factor. In addition, structure design that led to stress concentration contributed to the failure as external factor. Finally, fatigue fracture happened at the reduce section of the pump shaft.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1004-1005)

Pages:

1401-1405

Citation:

Online since:

August 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Tao Sun, Yanting Feng, Xuexia Xu, et al. Hot Working Technology, 2013, 42(14): 194-195(in Chinese).

Google Scholar

[2] Hongying Li, Xiongjie Su, Guang Chen, et al. Materials science and technology, 2013, 21(5): 82-87(in Chinese).

Google Scholar

[3] Youtang Li, Qiang zhou. Journal of Lanzhou University of Technology, 2013, 39(5): 159-161(in Chinese).

Google Scholar

[4] Baolan Gu, Xuetao Zhang, Tong Xu. Physics Test, 2013, 49: 327-329(in Chinese).

Google Scholar