Experimental Study on Discharge Coefficients of Windward Window in Buildings with Wind-Driven Cross Ventilation

Article Preview

Abstract:

Focus on the prediction of flow rates in buildings under natural ventilation, the investigation conducted a series of model rooms with cross ventilation. The impact of window-wall ratios, windows configurations as well as corresponding flow rates was investigated. The object of this investigation is to analyze characteristics of windward window opening discharge coefficient by measuring static pressure difference and the flow rate through windows. The conclusion are as follows: For large openings, the discharge coefficient of windward window opening increases as the window-wall ratio grows up; With windward window-wall ratio of 44.4% and 11.1%, the discharge coefficient of windward openings is almost irrelevant to flow rate and less affected by leeward window area; However, with windward window-wall ratio of 2.78%, the discharge coefficient increases slightly as flow rate rises, and the larger the area of leeward opening is, the smaller the discharge coefficient of windward opening becomes.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1008-1009)

Pages:

1061-1067

Citation:

Online since:

August 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] A. Mochida, H. Yoshino, T. Takeda, T. Kakegawa, S. Miyauchi: Journal of Wind Engineering and Industrial Aerodynamics Vol. 93 (2005), p.437–449.

DOI: 10.1016/j.jweia.2005.02.003

Google Scholar

[2] Li Yuguo, Delsante A, Chen Zhengdong, et al: Building and Environment Vol. 36 (2001), pp.851-858.

Google Scholar

[3] BS 5925, Code of Practice for Design of Buildings: Ventilation Principles and Designing for Natural Ventilation, British Standards Institution, London, UK, (1980).

Google Scholar

[4] H.B. Awbi, Ventilation of Buildings, Taylor and Francis, London, England, (1991) p.61.

Google Scholar

[5] P.F. Linden, The Fluid Mechanics of Natural Ventilation, Annual Review of Fluid Mechanics 31 (1999), p.201–238.

DOI: 10.1146/annurev.fluid.31.1.201

Google Scholar

[6] J.W. Axley, Analytical methods and computing tools for ventilation, in: M. Santamouris, P. Wouters (Eds. ), Building Ventilation: The State of the Art, Earth-scan, London, England, 2006, p.39–49.

Google Scholar

[7] P. Karava, T. Stathopoulos, A.K. Athienitis: International Journal of Ventilation Vol. 3 (2004), p.255–266.

Google Scholar

[8] C.R. Chu, Y.H. Chiu, Y.W. Wang: Energy and Buildings Vol. 42 (2010), p.667–673.

Google Scholar

[9] C. R. Chu, Ren-Hao Chen, Jhao-Wei Chen: Energy and Buildings Vol. 43 (2010), pp.2631-2637.

Google Scholar

[10] Li Zhang. Analysis and Discussion about the Resistance Characteristics of the Building Window. Master Thesis, university of Chang'an, China; 2012 (in Chinese).

Google Scholar

[11] Seifert J, Yuguo Li, Axley J, et al: Journal of Wind Engineering and Industrial Aerodynamics Vol. 94 (2006), pp.925-947.

DOI: 10.1016/j.jweia.2006.04.002

Google Scholar

[12] Yongwei Gao, et al. Experimental Hydromechanics Foundation. Northwest Industrial University, Xi'an, China, 2011 pp.26-28. (in Chinese).

Google Scholar

[13] Y.H. Chiu, D.W. Etheridge: Journal of Wind Engineering and Industrial Aerodynamics Vol. 95 (2007), p.25–252.

Google Scholar