The Energy-Saving Retrofit of Axial Fan Based on Performances Test in a 300MW Unit

Article Preview

Abstract:

In a power plant of 300MW, the power consumption of its axial Induced Draft Fan (IDF) and Flue Gas Desulfurization (FGD) booster fan was high on the whole. So it is necessary to take measures to reduce the power consumption by energy-saving retrofit. Firstly, a series of test and optimization are carried out on its operational performances. Furthermore, several retrofit schemes are worked out. Then, based on a series of test about its operational characters, an evaluation on potential to save energy is carried out for the IDF and the FGD booster fan. Finally, according to the comprehensive analysis including technical economic, difficulty and reliability, it is of the best scheme to carry out the frequency conversion retrofit for IDF. In fact, its effect is good after the retrofit is conducted, namely, the energy-saving index is almost the same as from evaluation. Obviously, the evaluation as for performance test is quite accurate and can avoid several problems likely to occur in frequency conversion retrofit.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

192-197

Citation:

Online since:

August 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] LIU Jiayu. Discussion on energy-saving of inland power plant fan[J]. Fan technology, 2007(3): 50-55.

Google Scholar

[2] CHE Changyuan. Energy saving technologies on boiler fans[M]. Beijing: China Electric Power Press, (1999).

Google Scholar

[3] LU Zhihou, ZHAO Feng. Application of the motor of wind-driven generator[J]. Power Station Auxiliary Equipment, 2008(4): 37-41.

Google Scholar