Research on Automatic Checking of Protection Functions for Smart Substation

Article Preview

Abstract:

The considerable variability of architecture and function realization of smart substation, which differ from traditional substations, makes the range of protection function check no longer restricted to one device, so it is necessary to carry out thorough monitoring and testing for various inks of functional implementation [1-2]. For this purpose, the automatic checking of protection functions for smart substation is researched, and a scheme for the implementation of the automatic checking is designed [3-4]. By means of adding various checking manners to application software implementation of the devices of protection system for smart substation, the checking and detection of various function implementation links of the protection system are performed, and by use of the expert system based on Dempster-Shafer theory a real-time virtual checking scheme is configured and through real-time analysis on checking information the conclusion of the checking is obtained. The proposed scheme enhances the self-diagnosis and self-monitoring ability of protection system for smart substation and gives full play to the superiority in digital information acquisition and information interaction of digital substation, so it can be used to the checking during on-site commissioning, besides, partial functions can be also used to perform on-line monitoring of protections being operated [5-9].

You might also be interested in these eBooks

Info:

Periodical:

Pages:

200-207

Citation:

Online since:

September 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Gao Xiang, Zhang Peichao. Main features and key technologies of digital substation [J]. Power System Technology, 2006, 30(23): 67-71.

Google Scholar

[2] Zhang Peichao, Gao Xiang. Analysis of reliability and component importance for all-digital protective systems [J]. Proceeding of the CSEE, 2008, 28(1): 77-82.

Google Scholar

[3] Meng Hengxin, Liang Xu, Liu Yuzhuo, et al. Research on closed loop real time simulation system of relay protection for digital substation[J]. Power System Technology, 2010, 34(12): 198-203.

Google Scholar

[4] Zhou Chunxia, Zhan Rongrong, Jiang Jianning, etal. Dynamic simulation test for 500 kV digital substation [J]. Power System Technology, 2010, 34(6): 193-197.

Google Scholar

[5] Wu Junxing, Hu Minqiang, Wu Zaijun, etal. Testing of IEC 61850 based intelligent electronic device and substation automation system [J]. Power System Technology, 2007, 31(2): 70-74.

Google Scholar

[6] Wang Hesheng, Protection mode and on-site check in digitized substation[J]. Shang hai Electric Power, 2010(6): 357-359.

Google Scholar

[7] Ma Liping, Jiao Yanjun. Online checking system for power system protective system protective relaying[J]. Shanxi Electric Power, 2011(1): 41-44.

Google Scholar

[8] Wang Yini, Ou Zhangjun. Reasearch on the calibration of relay protection in digital substation[J]. East China Electric Power 2010(12): 1993-(1994).

Google Scholar

[9] Zhang Huijian, Sun Dan, Xu Ke.

Google Scholar