Design and Optimization of Dense Phase Desulfurization Tower

Article Preview

Abstract:

Dense flow absorber of desulfurization is a new type of semi dry flue gas desulfurization technology, desulfurization of flue gas is mainly in the dense phase absorption tower. By using the turbulence model in Fluent.14 software, three-dimensional numerical simulation of dense phase in different flue gas entrance tower height of internal flow field. Selection of k- ε model as the calculation model, using Simple algorithm. Selected from the flue gas 1m, 2mand 3m, simulation the flow field distribution, combined with the experimental analysis.The results show that the flue gas entrance height from the top of the 1m, the flow field distribution is uniform, the minimum pressure drop.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1044-1045)

Pages:

553-558

Citation:

Online since:

October 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Wang Yuejun, Liu Xueyan, Li Zeqing。Optimization Design of Semi-dry Flue Gas Desulphurization Reactor Based on The CFD. [J]. Environmental Engineering. 2013: 31(1)73-76.

Google Scholar

[2] Zhou Shanming , Jin Baosheng , Zhong Zhaoping, Sun Keqin. Hydrodynamic Simulation and Optimized Design of a Large sized Flue Gas Desulfurizer. [J]Journal of Southeast University (Natural Science Edition). 2005:20(3)270-274.

Google Scholar

[3] GONG Guo-zhuo, ect. Characterization and Modification of Inlet Configuration on Gas Flow in a Circulating Fluidized Bed Desulf urization Reactor. [J]Journal of China University of Mining & Technology2010: 39(1)104-108.

Google Scholar

[4] EL-BEHERY S M, HAMED M H, EL-KADI M A, et al. Prediction of air-solid flowin180°curved duct. Powder Technology . (2009).

DOI: 10.1016/j.powtec.2008.09.018

Google Scholar

[5] SongJianfei, PengYuanyuan, GuoBenling. Simulation on gas phase flow field with improved inlet configurations in CFB flue gas desulphurization tower . [J]Chinese Journal of Environmental Engineering, 2010, 4(10)2283-2286.

Google Scholar

[6] ZHANG Dong-hui1, WANG Zhuo-hui, SONG Cun-yi. Simulation study on desulfurization of sintering flue gas in a dense flow absorber, [J]Journal of University of Science and Technology Beijing. 2012: 34(11)1324-1331.

Google Scholar

[7] LI Shao-hua, SUN Ying-bo, WANG Hu. Numerical simulation analysis of the influence on temperature field by the arrangement of internal structural elements in the desulfurization towe. Journal of Shenyang Institute of Engineering(Natural Science. 2013: 9(1)19-23.

Google Scholar

[8] HONG Wen-peng, LIU Guang-lin, PEI Cai-fen. Influence of Entrance Angle on Gas-Liquid Flow Field in Ammonia Flue Gas Desulphurization Tower. Journal of Chinese Society of Power , 2012, (32)4: 326.

Google Scholar