Research on Concrete-Filled Rectangular Steel Tube Stiffeners and Axial Compression Bearing Capacity

Article Preview

Abstract:

Concrete-filled rectangular steel tube four sides restraint effect on the core concrete was weaker than the corner, which made the effect not significant. The paper studied a new kind of stiffening rib –PBL stiffener to strengthen restraint effect of concrete-filled rectangular steel tube , and evaluated its advantages compared with other stiffening ribs. 9 PBL stiffened concrete-filled rectangular steel tube columns under axial compressive load were tested. It also collected the test with other stiffened rids, such as straight ribs, binding bars, knee brace, steel reinforcement cage, steel bar stiffeners, saw tooth shaped stiffeners, stitching straight stiffeners and no rib concrete filled rectangular steel tube to compare. It evaluated increasing coefficient of bearing capacity by stiffening ribs. The results showed that: the PBL stiffeners and binding bar of concrete-filled rectangular steel tube bearing capacity was greater than other reinforcement measures by more than 20%; PBL stiffener could be a new prominent type of stiffener because of its excellent mechanical performance and simple construction.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1065-1069)

Pages:

1092-1096

Citation:

Online since:

December 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Yong-jian Liu, Ning Zhang, Jun-guang Zhang. Mechanical Behavior of concrete-filled square steel tube stiffened with PBL shear connector: submitted to Journal of Architecture and Civil Engineering(2012)(in Chinese).

Google Scholar

[2] Shi-cong Yang, Fu-min Wang, Ping Qu. Brief introduction to the core concrete's empty influence on the mechanical performance of concrete filled steel tube components submitted to Jounal of Chong Qing Jiao Tong University(2008) (in Chinese).

Google Scholar

[3] Yao-chun Zhang, Yong Chen. Experimental study and finite element analysis of square stub columns with straight ribs of concrete-filled thin-walled steel tube submitted to Journal of Building Structures (2006) (in Chinese).

DOI: 10.1016/j.tws.2018.02.024

Google Scholar

[4] Jun-Qing Xue, Chiaki Matsui. Effects of debonding on circular CFST stub columns submitted to Journal of Construction Steel Research (2012) (in Chinese).

Google Scholar

[5] Yong-jian Liu, Jun-guang Zhang. Experimental research on stub columns of concrete-filled steel box with longitudinal stiffener under axial load submitted to Journal of Building Structures, (2011) (in Chinese).

Google Scholar

[6] Cheng-xiang Xu, Chang-an Zhu. Experimental research on concrete-filled square thin-walled steel tubular stub columnswith steel bar stiffeners submitted to Journal of Building Structures (2009) (in Chinese).

Google Scholar

[7] Zheng-yu Yang. Reseach on static behaviour of square concrete-filled steel tubular stub columns with steel bar stiffeners, MASc thesis, Harbin Institute of Technology. at Harbin, China(2008).

Google Scholar

[8] Zhong Tao, Lin-hai Han, Zhi-bin Wang. Experimental behaviour of stiffened concrete-filled thin-walled hollow steel structural (HSS) stub columns submitted to Journal of Constructional Steel Research (2005).

DOI: 10.1016/j.jcsr.2004.12.003

Google Scholar

[9] Y.B. Kwon, J.Y. Song, K.S. Kon. The structural behaviour of concrete-filled steel piers[Z]. Proceedings of 16th Congress of IABSE. Iucerne,Switzerland University of Applied Sciences Fribourg. 2000: 16, 598-605.

DOI: 10.2749/222137900796299075

Google Scholar

[10] Dong-ye Wang, Zhong Tao, Lin-hai Han. Experimental study on ductility for stiffened concrete-filled thin-walled steel tubular columns with square sections, The Fifteenth National Conference on Structural Engineering (Volume II)(2006).

DOI: 10.1016/j.tws.2007.04.003

Google Scholar

[11] Hong Huang, An-ge Zhang, Yi Li. Experimental research and finite element analysis on mechanical performance of concrete-filled stiffened square steel tubular stub columns subjected to anxial compression submitted to Journal of Building Structures(2011).

Google Scholar

[12] Z.Q. He, J Cai. Calculation for bearing capacity of concrete-filed steel square tube column with binding bars subjected to axial load submitted to Industrial Construction (2008) (in Chinese).

Google Scholar

[13] J Cai, Y Long. Local buckling of steel plates in rectangular CFT columns with binding bars submitted to Journal of Constructional Steel Research (2009).

DOI: 10.1016/j.jcsr.2008.07.025

Google Scholar

[14] C Petrus, H.H. Abdul, A Ibrahim, et al. Experimental behaviour of concrete filled thin walled steel tubes with tab stiffeners submitted to Journal of Constructional Steel Research (2010).

DOI: 10.1016/j.jcsr.2010.02.006

Google Scholar

[15] Y.C. Zhang, Xu C, LU X. Experimental study of hysteretic behaviour for concrete-filled square thin-walled steel tubular columns submitted to Journal of Constructional Steel Research(2007).

DOI: 10.1016/j.jcsr.2006.04.014

Google Scholar

[16] H. B Ge, T Usami. Strength analysis of concrete-filled thin-walled steel box columns submitted to Journal of Constructional Steel Research. (1994).

DOI: 10.1016/0143-974x(94)90003-5

Google Scholar

[17] Y.C. Zhang. Research on square stub columns with oblique ribs of concrete-filled thin-walled steel tube under axial compression loading submitted to Journal of Southeast University(Natural Science Edition) (2006)(in Chinese).

DOI: 10.3390/ma12071098

Google Scholar

[18] Lin-hai Han, Zhong Tao. Study on behavior of concrete filled souare steel tubes under axial load submitted to China Civil Engineering Journal (2006) (in Chinese).

Google Scholar

[19] Lin-hai Han, Yong-fu Yang. Concrete-filled-steel-tube Columns with rectangular section submitted to China Civil Engineering Journal (2001) (in Chinese).

Google Scholar