Comparative Analysis on Built Environment between Ground and Underground Shopping Malls in Chongqing in P.R. China

Article Preview

Abstract:

An investigation study on built environment was carried out for ground shopping malls and underground shopping malls, in search of similarities and differences between them. Four representative shopping malls were investigated from 2012 to 2014 by means of testing and questionnaires. It analyzed the current situation of indoor thermal environment, light environment, acoustic environment as well as indoor air quality. The study found that no significant differences in indoor environmental parameters (including air temperature, relative humidity and air velocity) and people’s sensation vote to them, apart from draft sensation vote for the two types of shopping malls. Besides, both the average indoor illumination was far below the national standard especially for underground shopping malls. Moreover, Noise levels were basically the same and the satisfaction rate of acoustic environment of underground shopping malls was apparently inferior to that of ground shopping malls. Eventually, indoor air quality was not as undesirable as it was expected even measured in the two types. On the basis of studying, some practicable improvement measures were proposed.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1065-1069)

Pages:

1656-1660

Citation:

Online since:

December 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Yao Yang, Key Technology of Environment Quality Assurance for Urban Underground Space [M]. BEIJING: China Architecture & Building Press, (2010).

Google Scholar

[2] Zheng Gang, Problems and Measures of Indoor Environmental Quality in Unnderground Space[J]. Journal of Heating Ventilating and Air Conditioning, 2005, 35(9): pp.21-23.

Google Scholar

[3] Huang Chen, Built Environment [M]. Beijing: China Machine Press, (2005).

Google Scholar

[4] Meng Zhe, Comparative Investigation Study of Indoor Environment Quality in Shopping Malls in Chongqing [D]. Chongqing: Chongqing University of Science and Technology, (2014).

Google Scholar

[5] Miao Gaoyang, Investigation Study of Indoor Environment Quality in Underground Shopping Malls in Chongqing [D]. Chongqing: Chongqing University of Science and Technology, (2012).

Google Scholar

[6] ISO7726-1998, Thermal Environment-Instruments and Methods for Measuring Physical Quantities[S].

Google Scholar

[7] ANSI/ASHRAE55-2004, Thermal Environmental Conditions for Human Occupancy[S].

Google Scholar

[8] GB50034-2013, Standard for Lighting Design of Buildings [S].

Google Scholar

[9] GB3096-2008, Environmental Quality Standard for Noise [S].

Google Scholar

[10] GBT17094-1997, Hygienic Standard for Carbon Dioxide in Indoor Air [S].

Google Scholar

[11] Li Wenjie, Liao Xinxue, Miao Gaoyang and Zhou Xinzhi, Analysis on Built Environment in Underground Shopping Malls in Chongqing in P.R. China [J]. Advanced Materials Research, 2012, 599: pp.233-236.

DOI: 10.4028/www.scientific.net/amr.599.233

Google Scholar