The Research on Relay Protection Settings On-Line Verification System Application in Smart Grid

Article Preview

Abstract:

The intelligrid-oriented on-line relay settings verification system based on EMS real-time data are discussed, with related software system designed and fulfilled. Firstly, the research background and current situation of on-line relay settings verification system are summarized. Secondly, the on-line relay settings verification system's general principle, hardware and software design are mainly discussed. And this paper shows the designed hardware structure diagram, the software structure diagram. And the flowchart of main procedure is given. Thirdly, the methods of dealing with EMS real-time data of the on-line verification system are discussed in detail. The verifying principles of sensitivity & selectivity of relay protection are given definitely. It is able to simulate two simultaneous faults, faults in network oscillation, and faults during auto-reclosing. It checks reliability & sensitivity of relay settings under these circumstances. Finally, considering substation-area and wide-area relay protections, this paper points out some key problems of on-line relay settings verification system to be resolved, and its application prospect.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1070-1072)

Pages:

1378-1383

Citation:

Online since:

December 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Wang Zengping, Liu Guoping, Qiu Xiangdong, et al. Realization of online relay protection setting value adjustment[J]. Power System Protection and Control, 2012, 40(1): 127-130.

Google Scholar

[2] Tao Jiayan. Research on EMS Real-Time Data Matching and Minimum Break Points Set in Relay Settings Verification[D]. Huazhong University of Science and Technology, (2012).

Google Scholar

[3] DUAN Xian-zhong, YANG Zeng-li, CHENG Xiao.Performance analysis of relay settings determined according to off-line calculation and on-line calculation[J]. Automation of Electric Power Systems,2005,29(19):58-61.

Google Scholar

[4] Lü Ying,WU Wen-chuan, et al. Development and application of an on-line relay setting coordination system[J]. Power System Technology, 2008,32 (8):15-20.

Google Scholar

[5] XIN Yao-zhong, TAO Hong-zhu, LI Yi-song, et al. E language for electric power system model description[J]. Automation of Electric Power Systems, 2006, 30(10): 1-5.

Google Scholar

[6] Liu Qin. Theory Study and System Development of Relay Settings Verification Based on EMS Real-time Information[D]. Huazhong University of Science and Technology, (2011).

Google Scholar

[7] Ren Long. Research of On-line Check System of Relay Protection Setting Value[D]. North China Electric Power University, (2012).

Google Scholar

[8] Xiao Jian, Wen Fushuan. Wide-area Protection and Its applications[J]. Proceedings of the CSU-EPSA, 2008, 20(4): 22-35.

Google Scholar

[9] Yi Jun, Zhou Xiao-xin. A Survey on Power System Wide-Area protection and Control[J]. Power System Technology, 2006, 30(8): 7-12.

Google Scholar