Study on the Optimum Location of PSS in Power Systems

Article Preview

Abstract:

Power system stabilizer in a power system is a closed-loop controller. The conventional participation factor method just considers the effect of PSS input signal. When the system stress is heavier, it may give misleading results. Based on the participation factor of modal analysis, an integrative participation factor is proposed to determine the optimum PSS location. The integrative participation factor takes into account both the input and control effect of PSS controllers. The case studied in 2-area 4-generator power system power system confirms that the integrative participation factor is more reasonable and effective than the participation factor method.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1070-1072)

Pages:

892-896

Citation:

Online since:

December 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] F.P. de Mello, P.J. Nolan, T.F. Laskowski, J.M. Undrill. Coordinated application of stabilizers in multimachine power systems[J]. IEEE Trans. on Power Apparatus and Systems, 1980, 99(3): 892-901.

DOI: 10.1109/tpas.1980.319717

Google Scholar

[2] Y.Y. Hsu, C.L. Chen. Identification of optimum location for stabilizer applications Using participation factors[J]. IEEE Proc on Gener. Trans & Distrib. 1987, 134(3): 238-244.

DOI: 10.1049/ip-c.1987.0037

Google Scholar

[3] C.L. Chen, Y.Y. Hsu. An efficient algorithm for design of decentralized output feedback power system stabilizer[J]. IEEE Trans. on Power Systems, 1988, 3(3): 999-1004.

DOI: 10.1109/59.14553

Google Scholar

[4] P. Kundur, M. Klein, G. J. Rogers and M. S. Zywno. Application of power system stabilizers for enhancement of overall system stability[J]. IEEE Trans. on Power Systems, 1989, 4(2): 614–626.

DOI: 10.1109/59.193836

Google Scholar

[5] Kundur P. Power system stability and control[M]. McGraw-Hill Inc., New York, (1994).

Google Scholar

[6] G. Rogers. Power System Oscillations[M]. Kluwer Academic Publishers, USA, (2000).

Google Scholar

[7] E. Z. Zhou, O. P. Malik and G. S. Hope. Theory and method for selection of power system stabilizer location[J]. IEEE Trans. on Power Systems, 1991, 6(2): 170–176.

DOI: 10.1109/60.73804

Google Scholar

[8] S. Liu, A.R. Messina, V. Vittal. Assessing placement of controllers and nonlinear behavior using normal form analysis[J]. IEEE Trans. on Power Systems, 2005, 20(3): 1486-1495.

DOI: 10.1109/tpwrs.2005.852052

Google Scholar

[9] B. P. Padhy, S. C. Srivastava, and N. K. Verma, Robust wide-area TS fuzzy output feedbackcontroller for enhancement of stability in multimachine power system, IEEE Syst. J., vol. 6, no. 3, p.426–435, Sep. (2012).

DOI: 10.1109/jsyst.2011.2165639

Google Scholar

[10] R. Diao, Z. Huang, N. Zhou, Y. Chen, F. Tuffner, J. Fuller,S. Jin, J. E Dagle, Deriving optimal operational rules for mitigating inter-area oscillations, Power Systems Conference and Exposition, Phoenix AZ USA, March (2011).

DOI: 10.1109/psce.2011.5772564

Google Scholar