Energy Efficiency Measures for a High-Tech Building with a Solar Roof

Article Preview

Abstract:

This paper presents the implementation of energy efficiency measures in a building that consists of office, lab and clean room area. Total Performance Oriented Optimization and Retrofits (TPORs) were implemented. 594 kW solar panels were installed on the roof and connected to the electrical grid during the optimization process. Ten power meters were installed throughout the building to measure the total building electricity demand, solar generated electricity demand, HVAC and non-HVAC-equipment demand to quantify the energy savings from the implementation of the energy efficiency measures and savings from the solar panels. The electricity savings from optimization on the HVAC system is about 7,209,000kWh/year (194.4kWh/m2-year), which is about 30% of the total building electricity consumption with peak demand reduction of 935 kW. There savings come from the solar panel is 811,925 kWh/yr; however, it effectively reduced the peak electricity demand by 302.6 kW.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1073-1076)

Pages:

1233-1238

Citation:

Online since:

December 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] ASHRAE (2011). ASHRAE Handbook-HVAC Applications. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, Chapter 42.

Google Scholar

[2] Y. Lin, N. Nassif, M. Liu (2014). Implementation of Energy Efficiency Measures in a Semiconductor Building., Energy Engineering, Journal of the Association of Energy Engineers (AEE) , 111(4), 34-58.

DOI: 10.1080/01998595.2014.10844607

Google Scholar

[3] T. Xu, B. Tschudi, G. Bell, E. Mills, D. Sartor (2011). High-tech buildings market transformation project. http: /hightech. lbl. gov/Documents/cleanrooms/Cleanroom_Benchmarking/Bench marking_Pubs/LBNL49112. pdf.

Google Scholar

[4] Y. Song, Y. Akashi, J. Yee (2008). A study on the energy performance of a cooling plant system: Air-conditioning in a semiconductor factory., Energy and Buildings, 40 (8), 1521–1528.

DOI: 10.1016/j.enbuild.2008.02.003

Google Scholar

[5] J. Tsao, S. Hu, T. Xu, D. Y.L. Chan (2010). Capturing energy-saving opportunities in make-up air systems for cleanrooms of high-technology fabrication plant in subtropical climate., Energy and Buildings, 42(11), 2005–(2013).

DOI: 10.1016/j.enbuild.2010.06.009

Google Scholar

[6] T. Xu (2008). Characterization of minienvironments in a cleanroom: Assessing energy performance and its implications., Building and Environment, 43(9), 1545–1552.

DOI: 10.1016/j.buildenv.2007.09.003

Google Scholar

[7] S. Hu, J. Wu, D.Y.L. Chan, R. T. Hsu, J.C. Lee (2008) Power con-sumption benchmark for a semiconductor clean room facility system., Energy and Buildings, 40(9), 1765–1770.

DOI: 10.1016/j.enbuild.2008.03.006

Google Scholar

[8] IPMVP (2002). International performance measurement & veri-fication protocol. http: /www. ipmvp. org.

Google Scholar