Research and Design on On-Line Contact of High Voltage Switch Circuit Breaker Temperature Rise Monitoring Device

Article Preview

Abstract:

In order to make on-line monitoring on the temperature of high voltage switch circuit breakerand find outthermal fault in time. This paper puts forward a new method with radio frequency and magnetic saturation power supply technology to make on-line monitoring on the temperature of high voltage switch circuit breaker, it designs the high voltage switch circuit breaker contact temperature online monitoring device. The device mainly includes monolithic temperature collector and data receiver, they transmit data wirelessly, and this makes high temperature monitoring terminal and the data receiving terminal completely electrical isolated. Integrated temperature collector doesn’t need external power supply, it uses small CT saturation technology for continuous power. The experiment shows that the temperature error is ±2°C, it can meet online temperature monitoring requirements of high voltage switch circuit breaker contact.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1092-1093)

Pages:

310-315

Citation:

Online since:

March 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Ma Donghua ect. Multimedia sensor network and its research progress. Journal of software, 2006, 17(9): 2013-(2028).

Google Scholar

[2] Long Weimin. Environmental protection of Long distance transmission line - corona interference. [J]. Power transmission and substation technology in Guangdong, 2006 (2) : 12-155.

Google Scholar

[3] M.S. Sachder, M M Giray,A Least Error Suares Technique for Determing Power System Frequency[J],Ieee Trans on Pas Vol. Pas-104, No 2, February (1985).

DOI: 10.1109/tpas.1985.319059

Google Scholar

[4] Lin Xiaoyu, Analysis on high voltage transmission line corona discharge electromagnetic radiation impact [J], electric power environmental protection, 2004, 20(3): 60-62.

Google Scholar

[5] Wang Shouli, Environmental protection of high voltage transmission lines [J], electric power technology in Yunnan, 2004, 32(2): 11-14.

Google Scholar

[6] Xie Shuyong, Wang Yun, High-voltage transmission conductor corona characteristics [J], high voltage electric equipment, 1996, 32(5): 21-23.

Google Scholar

[7] Tang Ju, Zhu Wei, Sun Caixin etc, GIS partial discharge uhf detection [J], high voltage technology, 2003, 29(12): 24-25.

Google Scholar

[8] Ji Feng, Anti-interference ability and electromagnetic compatibility ofmixed signal circuit [J], guidance and fuze, 2003, 24(3): 42-45.

Google Scholar

[9] Xu Hua, Wen Xishan, Shu Xiang. The environmental impact of uhv transmission [J],  electric power in Hubei, 2004, 28(4): 52-53.

Google Scholar