Influences Discipline of Tunnel Blasting Vibration on 20 Floors Reinforced Concrete Frame-Shear Wall Structure Building
Abstract:
According to the 20 layers reinforced concrete frame-shear wall structure building, we carried on blasting vibration monitoring in Qingdao Cross-harbor Tunnel Guide Line Project. The monitoring data of vertical vibration velocity and vertical vibration frequency had been analyzed. The results show vertical vibration velocity and vertical vibration frequency had part of intrinsic association. Vertical vibration velocity was enlarged on the top of the building. Vertical vibration frequency was in the range of 101-102 order of magnitude.