p.73
p.77
p.81
p.86
p.90
p.94
p.98
p.102
p.108
Clamping Accuracy Detection and Display System of Integral Turbine-rotor in Molecular Pump
Abstract:
Molecular pump with magnetic suspension is an important vacuum extractor. The machining accuracy of turbine-rotor has crucial influence on the key parameters of molecular pump, such as pumping speed, compression ratio. A clamping accuracy detection and display system of semi-fished turbine-rotor was established. The maximum coaxiality error and its position could be detected, displayed and recorded easily. With a precision fine tuning device, coaxiality error could be reduced from 30µm to 10µm. This system effectively reduces the turbine-rotor’s centrifugal force, and increases the stability of molecular pump with magnetic suspension.
Info:
Periodical:
Pages:
90-93
Citation:
Online since:
May 2011
Authors:
Keywords:
Price:
Сopyright:
© 2011 Trans Tech Publications Ltd. All Rights Reserved