Research on FRP-Reinforced Concrete Exposure Test

Article Preview

Abstract:

The paper makes an analysis of the selected location and feasibility of the exposure test ground in the real marine environment, and the endurance test of the FRP- reinforced concrete built-up beam has been carried out on the exposure test ground. After 6 month and 12 month’s exposure test, the beams' mechanic performance and the chloride ion content in different depths have been determined. The results show that after the exposure test, the beams' ultimate capacity has been greatly decreased to a certain extent, and the FRP board can effectively prevent chloride from penetrating.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 250-253)

Pages:

1177-1182

Citation:

Online since:

May 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Naifeng Hong. Corrosion and Durability of Reinforced concrete infrastructure. Civil engineering safety and durability [M]. Beijing: China architecture & building press, 2003. 76-83

Google Scholar

[2] Shiqin He. Experimental Studies on Durability of Reinforced Concrete Members in Chloride Environment [D]. Dalian: Dalian University of Technology, (2004)

Google Scholar

[3] Yanlei Wang, Jinping Ou. Fundamental mechanical behavior of innovatively designed hybrid FRP-concrete beams[J]. Journal of Xian building technology university (Natural Sciences),2006, 38(4):455-462

Google Scholar

[4] Lieping Ye, Peng Feng. Applications and development of FRP in civil structures [J]. China Civil Engineering Journal, 2006, 9(3):24-36

Google Scholar

[5] Baolan Zhang, Shushan Wei. Test for Reinforced Concrete Structure at Sea Port of South China after Ten Years' Expose [J]. Port & Waterway Engineering,1999,3:6-13

Google Scholar

[6] Qingling Wu; Hongfa Yu; Jiachun Wang; Limin Liang. Chloride ion diffusion characteristics of concrete in field marine regional environment[J]. Journal of Hehai University(Natural Sciences).2009,37(4),410-414

Google Scholar

[7] Sreejith V. Nanukuttan, Lulu Basheer, W. John McCarter, Des J. Robinson, andP. A. Muhammed Basheer. Full-Scale Marine Exposure Tests on Treated and Untreated Concretes—Initial 7-Year Results. ACI Materials Journal, 2008, 105(10):81-87

DOI: 10.14359/19210

Google Scholar

[8] Huitao Ren, Aping Wang, Anni Hu. Durability on Reinforced Concrete Structures Strengthening with Fiber Reinforced Plastic (FRP) [C]. The second session of the National Civil fiber reinforced composites (FRP) Symposium on Applications. Beijing: Tsinghua University Press, 2002:338-342

DOI: 10.1533/9780857098955.1.148

Google Scholar

[9] Luoshu Gong, ChunPu. Liu. Durability and protection of concrete repair. Beijing: China architecture & building press, (1990)

Google Scholar