The Design of Electroporation Device Based on Dielectrophoresis with its Application on the Control of Monoplast

Article Preview

Abstract:

μTAS is aimed at applying the operation of biochemical analysis on microchips, and its advantages have drawn great attention. This paper demonstrates a different approach to realize the capture of single cells [1]. By exerting electrode on the bottom or the top of fluid piping, it can produce the non-uniform electric field required by dielectrophoresis device. As for the application, it mainly lies in three aspects: electroporation of monoplast, dynamic fostering of monoplast array, and cell graphical techniques [2].

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 311-313)

Pages:

1336-1339

Citation:

Online since:

August 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Manz A, Graber N, Widmer H M. Miniaturized total chemical analysis systems: A novel concept for chemical sensing. Sensors and Actuators B: Chemical, 1990, 1:244–248.

DOI: 10.1016/0925-4005(90)80209-i

Google Scholar

[2] Pohl H A. Dielectrophoresis. UK: Cambridge University Press.

Google Scholar

[3] Yu-Cheng Lin, Chung-Min Jen, Ming-Yuan Huang, et al. Electroporation microchips for continuous gene transfection. Sensors and Actuators B: Chemical, 2001, 79:137–143.

DOI: 10.1016/s0925-4005(01)00859-0

Google Scholar

[4] Yu-Cheng Lin, Min Li, Chao-Chin Wu. Simulation and experimental demonstration of the electric field assisted electroporation microchip for in vitro gene delivery enhancement. Lab on a Chip, 2004, 4:104–108.

DOI: 10.1039/b312804k

Google Scholar

[5] Michelle Khine, Adrian Lau, Cristian Ionescu-Zanetti, et al. A single cell electroporation chip. Lab on a Chip, 2005, 5:38–43.

DOI: 10.1039/b408352k

Google Scholar

[6] J Seo, C Ionescu-Zanetti, R Lal, et al. Integrated multiple patch-clamp array chip via lateral cell trapping junctions. Applied physics letters, 2004, 84:1973–1975.

DOI: 10.1063/1.1650035

Google Scholar

[7] A Valero, J N Post, J W van Nieuwkasteele, et al. Gene transfer and protein dynamics in stem cells using single cell electroporation in a microfluidic device. Lab on a Chip.

DOI: 10.1039/b713420g

Google Scholar

[8] Yong Huang, Boris Rubinsky. Flow-through micro-electroporation chip for high e_ciency single-cell genetic manipulation. Sensors and Actuators A: Physical, 2003, 104:205–212.

DOI: 10.1016/s0924-4247(03)00050-5

Google Scholar

[9] Sang Kyung Kim, Jae Hyun Kim, Kwang Pyo Kim, et al. Continuous Low-Voltage dc Electroporation on a Microfluidic Chip with Polyelectrolytic Salt Bridges. Analytical Chemistry, 2007, 79(20):7761 –7766.

DOI: 10.1021/ac071197h

Google Scholar

[10] Jeong Ah Kim, Keunchang Cho, Young Shik Shin, et al. A multi-channel electroporation microchip for gene transfection in mammalian cells. Biosensors and Bioelectronics, 2007, 22:3273–3277.

DOI: 10.1016/j.bios.2007.02.009

Google Scholar

[11] Hang Lu, Martin A Schmidt, Klavs F Jensen. A microfluidic electroporation device for cell lysis. Lab on a Chip, 2005, 5:23–29.

DOI: 10.1039/b406205a

Google Scholar