Study on the Novel Label Free Impedimetric Immunosensor for Aflatoxin B1 Based on Poly(o-phenylenediamine) Film Modified Gold Electrode

Article Preview

Abstract:

A label free impedimetric immunosensor for the determination of aflatoxin B1 (AFB1) was fabricated by immobilizing anti-AFB1 onto Poly o-phenylenediamine (PoPD) electropolymerized film modified gold electrode by glutaraldehyde (GA) cross-linking. An electrochemical interfacial modeling of biomolecular recognition was recommended and reasonably interpreted. EIS technology was employed for the quantitative determination. The linear detection concentration ranges of AFB1 were 0.03~0.1 μg/mL and 0.1~0.7 μg/mL. The detection limit was 2.8×10-8μg/mL. The immunosensor could be reused more than 10 times when renewed by HCl-Glycine buffer solution (pH 2.6).

You might also be interested in these eBooks

Info:

Periodical:

Pages:

385-389

Citation:

Online since:

August 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] J. Stroka and E. Anklam: TrAC Trends in Analytical Chemistry Vol. 21 (2002), p.90.

Google Scholar

[2] J. Stroka and E. Anklam: Journal of Chromatography A Vol. 904 (2000), p.263.

Google Scholar

[3] N. H. S. Ammida, L. Micheli, S. Piermarini, D. Moscone and G. Palleschi: Analytical Letters Vol. 39 (2006), p.1559.

DOI: 10.1080/00032710600713248

Google Scholar

[4] N.H.S. Ammida, Lawa. Micheli and G. Palleschi: Analytica Chimica Acta Vol. 520 (2004), p.159.

DOI: 10.1016/j.aca.2004.04.024

Google Scholar

[5] S. Piermarini, L. Micheli and N. H. S. Ammida: Biosensors and Bioelectronics Vol. 22 (2007), p.1434.

Google Scholar

[6] K. Kerman, N. Nagatani, M. Chikae, T Yuhi, Y. Takamura and E. Tamiya: Analytical Chemistry Vol. 78 (2006), p.5612.

DOI: 10.1021/ac051762l

Google Scholar

[7] J. Parellada, A. Narváez, M. A. López, E. Domíngueza, J. J. Fernándezb, V. Pavlovb and I. Katakis: Analytica Chimica Acta Vol. 362 (1998), p.47.

DOI: 10.1016/s0003-2670(98)00087-7

Google Scholar

[8] S. Piermarini, L. Micheli and N. H. S. Ammida: Biosensors and Bioelectronics Vol. 22 (2007), p.1434.

Google Scholar

[9] R. M. Pembertona, R. Pittsonb, N. Biddleb, G. A. Dragoc and J. P. Hart: Analytical Letters Vol. 39 (2006), p.1573.

Google Scholar

[10] J. H. O. Owino, A. Ignaszak, A. Al-Ahmed, P. G. L. Baker, H. Alemu, J. C. Ngila and E. I. Iwuoha: Analytical and Bioanalytical Chemistry Vol. 388 (2007), p.1069.

DOI: 10.1007/s00216-007-1333-9

Google Scholar

[11] Jun Yano: Journal of Polymer Science Part A: Polymer Chemistry Vol. 33 (1995), p.2435.

Google Scholar