Numerical Simulation for Smoke Flow of the Underground Railway Tunnel Fire

Article Preview

Abstract:

The characteristics of tunnel fire are analyzed, and the numerical simulation of some tunnel of Shenyang railway is made with the CFD software star-ccm+ 5.02, which applies the field modeling method. A comprehensive understanding of tunnel fire characteristics and flue gas development are obtained, through analyzing the concentration field and temperature field, which may provide the theoretical background for evacuation design in tunnel fire. The effective measures of fire rescue and evacuation are also put forward.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 368-373)

Pages:

1454-1457

Citation:

Online since:

October 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Limin Peng and Xiaobing Liu:Underground Railway.( Railway Publishing House of China Press, BeiJing 2006)(In Chinese)

Google Scholar

[2] M. H. Zhong: China Safety Science Journal Vol. 11(2005),P. 10(In Chinese)

Google Scholar

[3] Z. L. Xie: China Safety Science Journal Vol. 7(2004),P. 21(In Chinese)

Google Scholar

[4] P. H. Zhang and N. Li: Journal of Shenyang Jianzhu University Vol.1(2011),P. 100, (In Chinese)

Google Scholar

[5] B. L: Journal of South China University of Technology Vol.2(2008), P.64(In Chinese)

Google Scholar

[6] P. H. Zhang and N. Li: Journal of Shenyang Jianzhu University Vol.4(2010),P. 756(In Chinese)

Google Scholar