Experiment Research on Vertical Poles Height Differences Effect of their Force Distribution in Formwork Support

Article Preview

Abstract:

Three formwork support units were experimental studied by heaped load. The experimental parameter is vertical poles height difference and their values are follows: 0mm, 2mm and 4mm. The effects on vertical poles force distribution were analyzed. The results showed the more height difference, the vertical poles force bearing distribution more uneven. Compared to higher column vertical poles, the low column vertical poles’ force bearing distribution are also more uneven.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 368-373)

Pages:

1638-1641

Citation:

Online since:

October 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Cai xuefeng, zhou jizhong, zhuang jinping. Research on Joint Slip Performance of Fastener-style Steel Pipe Formwork Support. China civil Engineering journal. 2009, 42(3):67-71.

Google Scholar

[2] Zhao diansheng, Tian xingchang, Zhang xuefeng, Zhou tiefeng. Global stability analysis of high formwork supporting frame with fastener style steel pipe system. Journal of zhejian G University of technology. 2007, 35(1):78-81. In Chinese.

Google Scholar

[3] JGJ130-2001. Technical code for safety of steel tubular scaffold with couplers in construction[S] In Chinese.

Google Scholar

[4] JGJ 162-2008. Technical code for safety of forms in construction. In Chinese.

Google Scholar

[5] Zhuang jinping,Cai xuefeng. Constitutive Relation Research on Anti-slipping Performance of Right-angle Fastener Steel Pipe Joints. Construction Technology, 2011, 40(336):79-81.

Google Scholar