A Novel Protection of Transmission Lines for Two ±500kV HVDC Systems Erected on the same Tower

Article Preview

Abstract:

Up to now, there is no precedent of applying two bipole lines (TBL) on the same tower technology of long-distance HVDC transmission project in the world. Owing to mutual influence between the two HVDC circuits on the same tower, the traditional protection of transmission line is faced with technical difficulties on fault pole identification, especially high grounded fault loop impedance. A new protection scheme of transmission lines for the double ±500kV HVDC circuits on the same tower is proposed. Based on electromagnetic decoupling method for TBL on same tower is proposed by analyzed the characteristic of coupling mutual induction, a four module components is proposed to decouple the network equation and analyze the fault modal network. On this basis, a novel method of fault pole identification based on the polarity comparison of line-mode back traveling wave is proposed. It has been made that validates the advantage of this novel protection strategy to identify the fault pole by simulation of PSCAD/EMTDC on the model of the TBL ±500kV HVDC system on the same tower in Xiluodu-Guangdong China.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 383-390)

Pages:

3669-3674

Citation:

Online since:

November 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Yan. Shi, Qing. Wang, and Ding-zhen. Nie, Comprehensive Study on Technology of Two Bipole Lines on the same tower for ±500 kV HVDC project , Power System Technology. Beijing, Vol. 30, pp.1-6, Novemver (2006).

Google Scholar

[2] Tao_xi . Zhu, and Chao. Wang, Discussion on the double circuit lines used in HVDC transmission system, Power System Protectyion and Control. Xuchang, Vol. 38, pp.42-46, January (2010).

Google Scholar

[3] Liang J, Elangovan S, and Devotta J B X. Application of wavelet transform in traveling wave protection , Electrical Power and Energy Systems, 2000, : 22.

DOI: 10.1016/s0142-0615(00)00033-8

Google Scholar

[4] Ling. Ai, and Wei-hua. Chen, Research on traveling wave protection criterion on HVDC transmission line , Relay. Xuchang, Vol. 31, pp.41-44, October (2003).

Google Scholar

[5] H.W. Dommel and W. S Meyer, Computation of electromagnetic transients, [J]. Proceedings of the IEEE, 1974, 62(7): 983-993.

DOI: 10.1109/proc.1974.9550

Google Scholar

[6] Jing Zhou, Weimin Ma, Yan Shi, and Wei Han, Study of Reliability for the Double Circuits on the Same Tower of Ge-Nan DC project , High Voltage Engineering . Wuhan, Vol. 33, pp.152-155, January (2007).

Google Scholar

[7] E.W. Kimbark, Transient Overvoltages caused by Monopolar Ground Fault on Bipole DC Line: Theory and Simulation, IEEE Trans on Power Apparatus and Systems, vol. PAS-89, No. 4, pp.584-592, (1970).

DOI: 10.1109/tpas.1970.292605

Google Scholar

[8] Gang. Wang, Zhi-keng. Li, and Hai-feng, Li, Transient based Protection for ±800 kV UHVDC Transmission Lines, Automation of Electric Power Systems. Nanjing, Vol. 31, pp.41-43, Novemver (2007).

DOI: 10.1049/cp:20060057

Google Scholar

[9] D. Naidoo and N.M. Ijumba, A Protection System for Long HVDC Transmission Lines, IEEE Power Engineering Society Inaugural Conference and Exposition in Africa, pp.150-155.

DOI: 10.1109/pesafr.2005.1611805

Google Scholar