Research of Wind Power into the Grid Based on Large-Capacity Parallel Converter Modules

Article Preview

Abstract:

The converters connected to the power grid, including rectifier and inverter. The rectifier uses DC voltage outer loop control method and the input current inner loop control method, three-phase inverter output current uses SPWM modulation. With the capacity of the system increasing, the capacity of a single converter can no longer meet the requirements, for improving the system's power grid, reliability and efficiency, converters can be paralleled. Parallel operation generates loop current; one of the effective methods of suppressing the loop current is to connect limiting inductance in the inverter AC side. Through simulation, gets the suitable inductance value, and researches the dead zone time affecting on the loop current. When the dead zone times of two modules are not equal, the loop current increases.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 383-390)

Pages:

5899-5906

Citation:

Online since:

November 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Ahmed T, Nishida K, Nakaoka M. Advanced control of PWMconverter with variable-speed induction generator [J]. IEEE Transactions on Industry Applications, 2006, 42(4): 934-945.

DOI: 10.1109/tia.2006.876068

Google Scholar

[2] Carrasco J M, Franquelo L G, Bialasiewicz J T, et al. Power electronic systems for the grid integration of renewable energy sources: a survey[J]. IEEE Transactions on Industrial Electronics, 2006, 53(4): 1002-1016.

DOI: 10.1109/tie.2006.878356

Google Scholar

[3] Tapia A, Tapia G, Ostolaza J X, et al. Modeling and control on a wind turbine driven doubly fed induction generator[J]. IEEE Transactions on Energy Conversion, 2003, 18(2): 194-204.

DOI: 10.1109/tec.2003.811727

Google Scholar

[4] Pan ChingTsai, Liao Yi-Hung. Modeling and coordinate control of circulating currents in parallel three-phase boost rectifiers[J]. IEEE Transactions on Industrial Electronics, 2007, 54(7): 825-838.

DOI: 10.1109/tie.2007.891776

Google Scholar

[5] Zhihong Ye, Boroyevich D, Jae-Young Choi, et al. Control of circulating current in two parallel three-phase boost rectifiers[J]. IEEE Transactions on Power Electronics, 2002, 17(5): 609-615.

DOI: 10.1109/tpel.2002.802170

Google Scholar

[6] Xing K, Lee F C, Boroyevich D, et al. Interleaved PWM with discontinuous space-vector modulation[J]. IEEE Transactions on Power Electronics, 1999, 14(5): 906-917.

DOI: 10.1109/63.788496

Google Scholar

[7] M. Young, The Technical Writer's Handbook. Mill Valley, CA: University Science, (1989).

Google Scholar

[8] Yang Yong, Ruan Yi, Shen Huanqing, Yang Ying. Inductance design of PWM converter AC side in wind power. Solar Energy, 2009, 3: 356.

Google Scholar

[9] Chen Huirong, research of inverter dead time effect and the typical compensation method. Master thesis of Tianjin University. 2006, 1.

Google Scholar