A Weak Current Detection Circuit Design of Organophosphorous Pesticides Rapid Detection Portable Instrument

Article Preview

Abstract:

In this paper, a weak current detection circuit is designed for developing organophosphorous pesticides rapid detection portable instrument. The detection principle is based on the electrochemical characteristic of enzyme catalyzing substrate of acetylcholinesterase biosensor for detecting pesticide residues. Based on the behavior of cyclic voltammograms (CV) of the acetylcholinesterase biosensor, the data acquisition and processing circuit of the weak current signals generated by the biosensor is designed, which including the I/V conversion, differential amplification , low-pass filter, A/D conversion etc. Eventually, the 0~5V voltage signal are obtained and they are proportional to the weak current from the enzyme biosensor. The designed detection circuit has a good consistence compared with electrochemical analysis instrument, which can establish a good base for developing organophosphorous pesticides rapid detection portable instrument.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 403-408)

Pages:

2569-2572

Citation:

Online since:

November 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] S. Laschi, D. Ogończyk, I. Palchetti and M. Mascini: Enzyme Microb. Technol. vol 40, (2007), p.485

Google Scholar

[2] A. N. Ivanov, L. V. Lukachova, G. A. Evtugyn, E. E. Karyakina, S. G. Kiseleva, H . C. Budnikov, A. V. Orlov, G. P. Karpacheva and A. A. Karyakin: Bioelectrochem, vol 55, (2002), p.75

DOI: 10.1016/s1567-5394(01)00163-3

Google Scholar

[3] A.Hildebrandt, R.Bragós, S.Lacorte, J.L. Marty: Sens. Actuators B: Chem,, vol 133, (2008), p.195

Google Scholar

[4] I. Marinov, K. Gabrovska, J. Velichkova: In. J. Bio.Macromo., Vol 44, (2009), p.338

Google Scholar

[5] J.M. Gong, L.Y. Wang, L.Z. Zhang: Biosens. Bioelectron, Vol 24, (2009), p.2285

Google Scholar

[6] D.Du, X. Huang, J.Cai, A. D. Zhang: Sens.Actuators B: Chem, Vol 127, (2007), p.531

Google Scholar

[7] N. Nagatani, A. Takeuchi, M.A. Hossain: Food Control, Vol 18, (2007), p.914

Google Scholar

[8] F. Ricci, F. Arduini, A. Amine: J. Electro. Analy.Chem,Vol 563, (2004), p.229

Google Scholar

[9] G.D. Jin, X.Y.Hu: Chin. J. Anal. Lab., Vol 27, (2008), p.14

Google Scholar

[10] E.Suprun, G.Evtugyn, H.Budnikov: Anal.Bioanal. Chem, Vol 383, (2005), p.597

Google Scholar