The Mix Design of Low Strength High Flowing Concrete with Low Cement Content Prepared by Manufactured Sand

Article Preview

Abstract:

Aiming at the engineering status of the shortage of natural sand and the contradictory between workability and strength surplus emerging in the design of low strength high flowing concrete (LHC), this paper has proposed a mix design method of LHC with low cement content prepared by manufactured sand (MS).And then verifies the feasibility of the method through experiments. Tests on slump, compressive strength and chloride ion diffusion coefficient were carried out and the results indicate that LHC with low cement content prepared by MS can be successfully produced using this method. Concrete designed by this method has low cement consumption and has utilized MS to replace NS as well as made full use of the industrial by-products of stone fines and fly ash. As a result, it is economical and ecological.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

201-206

Citation:

Online since:

December 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] P.K. Metha, Paulo J.M. Monteiro: Concrete Microstructure, Properties and Material (China Electric Power Press, 2008).

Google Scholar

[2] China Sand Association. GB/T 14684-2001 Sand for building. (China Standard Press, 2001).

Google Scholar

[3] Xu jian, Cai jiwei etc. The research status of manufactured sand and manufactured concrete. Science and Technology of Overseas Building Material Vol. 3 (2004), pp.20-24.

Google Scholar

[4] Santhanam M, Langerblad S. Current developments in self-compacting concrete. Ind Concr J Vol. 78 (2004), pp.11-22.

Google Scholar

[5] Nanthagopalan P, Santhanam M. Fresh and hardened properties of self-compacting concrete produced with manufactured sand. Cem Concr Compos Vol. 33(2011), pp.353-358.

DOI: 10.1016/j.cemconcomp.2010.11.005

Google Scholar

[6] China Academy of Building Research. GB/T 50080-2002 Standard for the test of performance on ordinary concrete (China Building Industry Press, 2003).

Google Scholar

[7] China Academy of Building Research GB/T 50081-2002 Standard for test method of mechanical properties on ordinary concrete (China Building Industry Press, 2003).

Google Scholar

[8] China Civil Engineering Society. CCES 01-2004 Guide to durability design and construction of concrete structures. (China Building Industry Press, 2005).

Google Scholar

[9] China Academy of Building Research. JTG 55-2000 Specification for mix proportion design of ordinary concrete (China Building Industry Press, 2000).

Google Scholar

[10] Liu shuhua, Leng faguang etc. Supplementary Cementing Material Used in Concrete. (China Building Material Press, 2010).

Google Scholar

[11] Violeta Bokan Bosiljkov. SCC mixes with poorly graded aggregate and high volume of limestone filler. Cem Concr Res Vol. 33 (2003), pp.1279-1286.

DOI: 10.1016/s0008-8846(03)00013-9

Google Scholar