Finite Element Analysis of Horizontal Reinforcement Ratio's Effect on Seismic Performance of Autoclaved Aerated Concrete Block Masonry

Article Preview

Abstract:

Non-linear analysis of autoclaved aerated concrete (AAC) block masonry composite wall with column has been conducted using finite element software ABAQUS. First, the finite element results were verified with laboratory results of full-scale specimens. Effects of horizontal reinforcement ratio on seismic performance were investigated. The analysis indicates that shearing strength of the wall is affected by the openings greatly. Seismic performance is improved with the increase of horizontal reinforcement ratio. The effect of vertical stress on wall without openings is more than that on wall with openings. Bearing capacity of walls without openings has a linear relationship with the horizontal reinforcement ratio. And bearing capacity of walls with openings is related to the place where the reinforcements are installed as well as the horizontal reinforcement ratio.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

326-330

Citation:

Online since:

December 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Wenfu Yang, Lu Gao, Lianyu Gao: New Building Materials, Vol. 2(2007), pp.22-26(In Chinese).

Google Scholar

[2] Shuming Tian: Study on static behavior and aseismic performance of autoclaved aerated concrete(AAC)block bearing walls( Tian jin University, Tian jin 2004).

Google Scholar

[3] Jinghai Yu, Wei Wang, Shuming Tian, et al: Low Temperature Architecture Technology, Vol. 5 (2007), pp.53-55.

Google Scholar

[4] Feng Xie, Jinghai Yu, Xiao-xiang Chen: Low Temperature Architecture Technology, Vol. 8(2009), pp.72-74.

Google Scholar

[5] Quanbin Zhao: Experimental research on the improvement of seismic behavior of load bearing masonry made of autoclaved aerated concrete(Tian jin University, Tian jin2006).

Google Scholar

[6] Peichun Ling: Experimental study on seismic behavior of autoclaved aerated concrete block composite walls( Beijing University of Technology, Beijing2011).

Google Scholar

[7] Huige Wu: Research on the Seismic Behavior of Autoclaved Aerated Concrete Block Bearing-wall with Core Columns(Beijing University of Technology, Beijing2011).

Google Scholar

[8] Industrial Standards of the People's Republic of China JGJ/T 17-2008: Technical specification for application of autoclaved aerated concrete(China Architecture & Building Press, 2008).

Google Scholar

[9] National Standards of the People's Republic of China GB50011-2010, Code for Seismic Design of Buildings(China Architecture & Building Press, 2010).

Google Scholar

[10] Yiping Shi and Yurong Zhou: Detailed Examples of Finite Element Analysis with Abaqus(China Machine Press, Beijing2006).

Google Scholar