An Damping Analysis on Local Vibration in Foundation of ‘four in one’ Nitric Acid Plant

Article Preview

Abstract:

‘four in one’ nitric acid plant is a key equipment to manufacture nitric acid. Its foundation is placed between the axial flow compressor and the expander, and has larger amplitude. Choosing the foundation of this machine as study subject, this paper analyses the biggest disturbance value of all vibration source in line with Code for design of dynamic machine foundation and by adding T-shaped kerfs on the box girder between the axial flow compressor and the expander. It also conducts harmonic response analysis on this foundation with the finite element method. By comparatively analyzing the displacement harmonic response figure of nodal points on the X, Y and Z axis in the foundation before and after adding the T-shaped kerfs, it indicates that T-shaped kerfs can dramatically mitigate the steady-state harmonic response amplitude.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

661-665

Citation:

Online since:

December 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] P.J. Murtagh. B.Basu. B.M. Broderick. Simple models for natural frequencies and mode shapes of towers supporting utilities. Computers and Structures, 2004;82, p.1745-p.1750

DOI: 10.1016/j.compstruc.2004.04.005

Google Scholar

[2] Dai Jin,Huang Songhe,Lin gang.Model Analysis of quad play nitric unit foundation based on ANSYS. Machinery, 2010;37,pp.37-39

Google Scholar

[3] Shu Gequn, Gao Wen zhi & Liu Yuehui., the Vibration and Noise of the Power Machinery. Tianjing: Tianjin University Press. 2008.

Google Scholar

[4] Hassan, Tasnim; Yimin, Zhu; Vernon C., Matzen. Simulation of Ratcheting in Straight Pipes Using ANSYS with an Improved Cyclic Plasticity Model. American Society of Mechanical Engineers, Pressure Vessels and Piping Division (Publication) PVP, v 340, pp.97-104, 1996, Seismic Engineering

Google Scholar

[5] Fassnacht, J.; Mutschler, P. Benefits and Limits of Using an Acceleration Sensor in Actively Damping High Frequent Mechanical Oscillations. Conference Record - IAS Annual Meeting (IEEE Industry Applications Society), v 4, pp.2337-2344, (2001)

DOI: 10.1109/ias.2001.955949

Google Scholar

[6] Dabrowski, Artur, Dabrowski, Artur. Energy-vector Method in Mechanical Oscillations. Chaos, Solitons and Fractals, v 39, n 4, pp.1684-1697, February 28, (2009)

DOI: 10.1016/j.chaos.2007.06.096

Google Scholar

[7] http://forum.simwe.com/forum.php?gid=112

Google Scholar