Research on Coordinated Control System of Unit Considering Regenerator System Based on Bilinear Fit

Article Preview

Abstract:

The validity of mathematical model direct impact the research result of the boiler-turbine coordinated control system. In this paper, applying the mechanical modeling method to set up model of boiler-turbine coordinated control system, and obtain its parameter by parameter identification. The mathematical model of boiler-turbine coordinated system has been modified and supplied by bilinear fit. And, for the practical problems that need to be resolved in research work of the coordination controlled object’s mathematical model, the mathematical analysis was carried out by the regenerator system integrated into heat balance of generator unit and a new type of simulation mathematical model of coordinated control system with regenerator system was researched. The mathematical model was verified through the simulation test. Based on the thought that dynamic energy and static energy separation, the of intelligent controller is structured and applied in coordination control system of generator unit. Simulation results show that not only load response and anti-interference ability are improved, but also dynamic overshoot greatly reduces

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 424-425)

Pages:

1179-1186

Citation:

Online since:

January 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] ZENG De-liang and LIU Ji-zhen: Drum boiler dynamic model and load/pressure increment predict model. In: Proceedings of the CSEE, vol. 20, pp.75-79(2000).

Google Scholar

[2] LU Jian-hong, CHEN Jian-qin, LIU Zhi-yuan, SHEN Jiong and CHEN Lai-Jiu: A study on fuzzy rules based and nonlinear modeis for thermal processes. In: Proceedings of the CSEE, vol. 22, pp.132-137(2002).

Google Scholar

[3] HOU Yi-wen, SHEN Jiong and LI Yi-guo: A simulation study on Load modeling of a thermal power unit based on waveletneural networks. In: Proceedings of the CSEE, vol. 23, pp.220-224(2003).

Google Scholar

[4] TIAN Liang, ZENG De-liang, LIU Ji-zhen and ZHAO Zheng: A simplified non-linear dynamic model of 330MW unit. In: Proceedings of the CSEE, vol. 24, pp.180-184(2004).

Google Scholar

[5] TIAN Liang, ZENG De-liang, LIUXin-ping and LIU Ji-zhen: A Simplified Non-Linear Dynamic Model of 500MW Unit. In: Power Engineering, vol. 24, pp.522-525(2004).

Google Scholar

[6] HAN Zhong-xu, Zhang zhi and Qi Xiao-hong: Analysis of linear increment mathematic model for multivariate boiler-turbine coordinated control object. In: Proceedings of the CSEE, vol. 25, pp.24-29(2005).

Google Scholar

[7] HAN Zhong-xu, QI Xiao-hong and LIU Min: A practical non-linear mathematical model of unit power plant and its application. In: Proceedings of the CSEE, vol. 26, pp.58-65(2006).

Google Scholar

[8] HAN Zhong-xu, QI Xiao-hong, LIU Min and ZHOU Guang: The Mathematical Model of YaoMeng unit 300MW Boiler-turbine Coordinated Control System. In: Power System Technology, vol. 30, pp.47-50(2006).

Google Scholar

[9] HAN Zhong-xu, GAO Chun-yu, QI Xiao-hong and LI Dan: Analysis on a type of mathematical model of thermal power plant. In: Proceedings of the CSEE, vol. 26, pp.125-130(2006).

Google Scholar

[10] HAN Zhong-xu, HUANG Huan-pao, Zhang Zhi, SUN Ying and LV Xiu-hong: Application of state feedback based on state observer in the coordinated control system of 300MW unit plant. In: China Electric Power, vol. 37, pp.60-65(2004).

Google Scholar

[11] HAN Zhong-xu, Wang Yu-xue, Qu Yun, ZHANG Sheng-gang, LI Sheng-hu and CHEN Tian-ji: Application of state feedback based on IFO-K�x in 4�300MW genarator unit of pingliang power plant. In: Proceedings of the CSEE, vol. 24, pp.233-237(2004).

DOI: 10.1109/icpst.2004.1460195

Google Scholar

[12] HAN Zhong-xu, Qi Xiao-hong, Pan Gang, ZHOU Guang, XIANG Tian-cheng LIU Dan and YU Guang-hui: A new design method of coordinate control system for once-through boiler and its engineering application. In: Proceedings of the CSEE, vol. 25, pp.121-127(2005).

Google Scholar

[13] HAN Zhong-xu, Zhang Zhi, LIU Min, QIU Zong-chang, DAI Guang-ming, HUANG Huan-pao, ZHU Ming-cheng and WU Fei-jun: Application And Design of Coordinated Control System for No. 1& 2 600MW Unit of Beilun Power Plant. In: Proceedings of the CSEE, vol. 25, pp.126-132(2005).

Google Scholar

[14] HAN Zhong-xu, QI Xiaohong and LIU Min: Mixed boiler-turbine coordinated control system mathematical model based on mechanism modeling and parameter identification. In: Proc. 2006 IEEE Conference on Industrial Electronics and Applications (2006).

DOI: 10.1109/iciea.2006.257086

Google Scholar

[15] HAN Zhong-xu, GAO Chun-yu, LI Dan: The Parameter Estimation for a Non-linear Mathematical Model of Boiler-turbine-generator Unit. In: Proc. 2007 IEEE Conference on Industrial Electronics and Applications, pp.1767-1770(2007).

DOI: 10.1109/iciea.2007.4318713

Google Scholar

[16] HAN Zhong-xu, QI Xiao-hong, ZHANG Zhi: A dynamic non-linear simulation model of boiler-turbine coordinated control system and its application. In: Proc. 2005 International Conference on Electrical Engineering (2005).

Google Scholar

[17] HAN Zong-xu, LI Dan and ZHOU Chuan-xin: On a Pathological Mathematical Model of Boiler-turbine-generator Unit. In: Proc. 2008 Asia Simulation Conference — 7th Intl. Conf. on Sys. Simulation and Scientific Computing, pp.1104-1109 (2008).

DOI: 10.1109/asc-icsc.2008.4675530

Google Scholar

[18] FANG Chong-zhi, XIAO De-yun: Process Distinguish, vol. I. Tsinghua University Press, Beijing (1988).

Google Scholar

[19] Li Yunze, Yang Xianyong: Long-term Dynamic Model and Simulation of Steam Turbines. In: Journal of Tsinghua University:Science and Technology,vol. 43, No. 2, pp.281-284 (2003).

Google Scholar

[20] Yu Daren, Guo Yufeng, Wang Xiaojuan: Dynamic Turbine Model with Regenerator. In: Proceedings of the CSEE,vol. 25, No. 14, pp.84-88 (2005).

Google Scholar

[21] HAN Zhong-xu, QI Xiao-hong and SUN Ying: The Method Heightening Response Rate to AGC by Analog Flexible Fuzzy Pre-feed Coal Control and Its Application. In: Power System Technology of China, vol. 30, supplement 2, pp.1-6 (2006).

Google Scholar

[22] Han Zhongxu, Huang Huanpao and Feng Jian: Application of the pre-feed coal control logic in CCS of power generation unit. In: China Electric Power, vol. 40, No. 3, pp.61-65 (2007).

Google Scholar

[23] HAN Zhong-xu, ZHOU Chuan-xin and ZHU Ze-lei: Concept of Analog Flexible Fuzzy Control and Its Application in Control System of Power Plant. In: 6th International Conference on Fuzzy Systems and Knowledge Discovery, Tianjin(2010).

DOI: 10.1109/fskd.2009.699

Google Scholar

[24] ZHUO Xu-sheng, ZHOU Huai-chun, WEN Zhong-lin, CHU Yun-tao and XU Hua,: Pressure and temperature dynamics in power plant superheater. In: Proceedings of the CSEE, vol. 27, pp.72-76 (2007).

Google Scholar

[25] HAN Zhong-xu, ZHOU Chuan-xin and ZHU Ze-le: Mathematical Model of Coordinated Control Object for Drum-boiler Turbine Generator Unit Considering Regenerator System. In: Proceedings of the CSEE, vol. 29, No. 35, pp.15-21 (2009).

Google Scholar