Long-Term Bonding Strength between Flue Gas Desulfurization Gypsum and Polymer Cement Mortar

Article Preview

Abstract:

The uncertainty of long-term bonding strength of flue gas desulfurization building gypsum and cement based construction materials is the major issue impeding the application of flue gas desulfurization building gypsum in construction. A polymer cement mortar is suggested to get high bonding quality with flue gas desulfurization building gypsum. Long-term bonding observation has been carried out to verify the bonding performance of suggested polymer cement mortar with flue gas desulfurization gypsum. The results show that the bonding strength is up to 3.0MPa, and the bonding between them is durable.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 446-449)

Pages:

1348-1351