Shaking Table Test Study on Mid-Story Isolation Structures

Article Preview

Abstract:

Mid-story isolation structure is developing from base isolation structures. As a complex structural system, the work mechanism of base isolation structure is not entirely appropriate for mid-story isolation structure, and the prolonging of structural natural period may not be able to decrease the seismic response of substructure and superstructure simultaneously. In this paper, for a four-story steel frame model, whose prototype first natural period is about 1s without seismic isolation design, the seismic responses and isolation effectiveness of mid-story isolation system with lead rubber bearing are studied experimentally by changing the location of isolation layer. Respectively, the locations of isolation layer are set at bottom of the first story, top of the first story, top of the second story and top of the third story. The results show that mid-story isolation can reduce seismic response in general, and substructure acceleration may be amplified.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 446-449)

Pages:

378-381

Citation:

Online since:

January 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Fulin Zhou. Seismic control of structures (Seismological Press , Beijing 1997)

Google Scholar

[2] Xiangzhen Li,Hailong Ou,Shu Lin.Earthquake engineering and engineering vibration(in Chinese), Vol. 22(2002), No.1,p.121

Google Scholar

[3] Ai Qi,Guochen Zheng. Journal of Building Structure(in Chinese),Vol. 30(2009), No.2,p.8

Google Scholar